TXT
묘사:
Liquid Level Switch
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
0.750 inches
MRC:
The length measured from the element to the extreme end of the power cable.ABJP
Power Cable Length:
140.000 inches
MRC:
The value,or range of values,of direct current potential for which the item is rated.ACYR
Dc Voltage Rating:
24.0 volts
MRC:
A measurement of the longest straight line across a circular cross-sectional plane.ADAV
Overall Diameter:
3.750 inches
MRC:
The means by which the item is actuated.AFLW
Actuation Method:
Buoyancy
MRC:
Indicates the type of electrical connection included on the item.AGBD
Electrical Connection Type:
Cable
MRC:
An indication of whether or not a facility/ies/ to accommodate a battery/ies/ is included.ALSF
Internal Battery Accommodation:
Included
MRC:
The amount of current at maximum rated voltage for which the item is designed.APGW
Current Rating At Maximum Rated Voltage:
500.0 milliamperes load
MRC:
The number of floats provided.AWAE
Float Quantity:
1
MRC:
The temperature at which the item operates.AWTN
Operating Tempurature Rating:
150.0 degrees fahrenheit
MRC:
The means of attaching the item.AXGY
Mounting Method:
Flange
MRC:
The installed position for which the item is designed.BBJX
Mounting Position:
Horizontal
MRC:
The designation that identifies the schematic diagram of the contact arrangement.BJKD
Contact Arrangement:
Spst
MRC:
An indication of whether or not a relay is included.BJKG
Relay:
Not included
MRC:
Indicates the type of liquid(s) for which the item is designed.BJKH
Liquid Type For Which Designed:
Aircraft fuel
MRC:
The aircraft fuel for which the item is designed.BJKJ
Aircraft Fuel For Which Designed:
All
MRC:
The distance of the effective travel of the float.BJKN
Float Effective Travel:
8.000 inches
MRC:
A measurement of the longest dimension from the mounting surface to the end of the item,which is designed to be inserted into the tank.BJKQ
Tank Insertion Length:
10.000 inches