TXT
묘사:
Fluid Filter Element
MRC:
The length of a straight line which passes through the center of the body,and terminates at the circumference.ABPM
Body Diameter:
3.000 inches
MRC:
The length of a straight line which passes through the center of a body,and terminates at the inside circumference.ADAS
Body Inside Diameter:
1.620 inches
MRC:
The size of the smallest particle which the element is capable of removing from the fluid which passes through the filtering material.ADNH
Filtration Rating In Microns:
10.0
MRC:
The direction in which the fluid is passed through the item.ADNK
Flow Direction:
Outside in
MRC:
Indicates the design type of the item.APGF
Design Type:
Limited
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the body.AZTL
Bodylength:
7.500 inches
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
By-pass valve
MRC:
An indication of the structure or characteristic of the filtering media.CRXW
Filtering Media Design:
Pleated single filtering media response
MRC:
The filtering system for which the item is designed to be used.CXZX
Filtering System For Which Designed:
By-pass flow
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Stainless steel filtering medium
MRC:
The type of media for which the item is designed.MEDA
Media For Which Designed:
Fuel/oil, hydrocarbon
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Cylindrical w/ container (rigid)