MRC:
An overall measurement between specified points of an item,in distinction from height.ABFY
Overall Depth:
5.000 inches
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
4.312 inches
MRC:
A measurement of the longest straight line across a circular cross-sectional plane.ADAV
Overall Diameter:
4.312 inches
MRC:
The environmental elements or conditions that an item is designed or protected to resist or withstand satisfactorily.ADZC
Environmental Protection:
Dustproof
MRC:
The pattern or arrangement that describes the mounting configuration of the item.ALGC
Mounting Configuration:
Four 0.281 in. Diameter mtg holes 3.250 in. By 3.250 in. Mtg centers
MRC:
The basic structure of the item.ALXF
Structural Design:
Sectional
MRC:
The alternating current values of root mean square potential which must be applied to the item for operation,expressed in volts.ANWD
Ac Operating Voltage Rating In Volts:
70.0
MRC:
The operating current for which the item is rated.APAM
Operating Current Rating:
0.38 amperes
MRC:
Indicates the type of current used with the contact/s/.APFX
Contact Current Type:
Ac and dc
MRC:
The maximum voltage rating at which the contact is rated,expressed in volts.APLS
Contact Maximum Voltage Rating In Volts:
125.0
MRC:
The amount of current at maximum rated voltage for which the contact/s/ is designed.APLT
Contact Current Rating At Maximum Rated Voltage:
500.0 milliamperes
MRC:
The maximum amount of current the contact/s/ will accommodate.APLW
Contact Maximum Rated Current:
1.5 amperes
MRC:
An indication of the amount of voltage for which the contact/s/ is designed to withstand at the maximum rated current.APLX
Contact Voltage Rating At Maximum Rated Current:
28.0
MRC:
The specific number of contact terminals included.APNG
Contact Terminal Quantity:
48
MRC:
The specific number of coil terminals included.APNH
Coil Terminal Quantity:
4
MRC:
An indication of whether or not the reset facilities are provided.APNR
Reset Facility Feature:
Not provided
MRC:
The amount of current required to activate the item.AXAZ
Pull-in Current:
1.4 amperes
MRC:
The direction of rotation for which the item is designed.AYSY
Rotation Direction For Which Designed:
Clockwise
MRC:
The opposition that the coil offers to the flow of direct current.BDFT
Coil Dc Resistance:
24.0 ohms
MRC:
The number of sections included.BWGP
Section Quantity:
4
MRC:
The number of coil winding(s) provided.CPWL
Coil Winding Quantity:
2
MRC:
The measurement of the shaft rotation,expressed in degrees.CPWT
Shaft Rotation In Deg:
360.0