측정 단위:
* special requirements. EA
부품 정보
2 rows of 3 rubber shock mounts spaced equally around periphery
TXT
묘사:
Direct Current Motor
MRC:
The distance measured in a straight line from the bottom to the top of an item.AAJT
Overall Height:
9.000 inches
MRC:
A measurement of the longest dimension of an item,in distinction from width.AAJU
Overall Length:
12.725 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.AAJV
Overall Width:
9.000 inches
MRC:
The length of a straight line which passes through the center of a hole,and terminates at the circumference.AAUB
Hole Diameter:
0.1770 inches single end
MRC:
A measurement between specified points of the hole,in distinction from height.AAZQ
Hole Depth:
0.0620 inches single end
MRC:
A measurement taken at right angles to the length of a keyway,in distinction from thickness.ABRR
Keyway Width:
0.1880 inches single end
MRC:
A measurement from the top surface to the bottom of the keyway groove.ABRV
Keyway Depth:
0.0940 inches single end
MRC:
The length of a straight line which passes through the center of a shaft,and terminates at the circumference.ABWV
Shaft Diameter:
0.7500 inches single end
MRC:
A measurement of the longest dimension of a keyway,in distinction from width.AFYS
Keyway Length:
0.7250 inches single end
Hole Center To Shaft End Distance:
0.290 inches single end
MRC:
The direction of rotation of a rotating shaft as viewed from the drive end.AKCT
Shaft Rotation Direction:
Clockwise single end
MRC:
The working period under which the item was designed to operate.AKPS
Duty Cycle:
Intermittent
MRC:
An indication of the feature/s/ of the inclosure.ANPZ
Inclosure Feature:
Open
MRC:
Indicates the specific arrangement in which wire is wound on a form or is formed by winding.AXCP
Winding Type:
Compound wound
MRC:
The means of attaching the item.AXGY
Mounting Method:
Flange
MRC:
Indicates the type and number of facilities by which the item is mounted.AXHR
Mounting Facility Type And Quantity:
4 slot
MRC:
The means of cooling used to maintain the required operating temperature of the item.BFMF
Cooling Method:
Natural convection ventilated
MRC:
The means by which the current is rated.BKPB
Current Rating Method:
Load
MRC:
The government or industrial specification or standard that defines the inclosure feature.BKPQ
Inclosure Specificationification:
Mil-std-108
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Horizontal mounting position
MRC:
The amount of electrical energy that can be dissipated.CNXS
Power Rating:
5.0000 horsepower output
MRC:
A measurement of the longest dimension of the shaft projection of an item,in distinction from width.CWCS
Length Of Shaft From Housing:
0.725 inches single end
MRC:
The length of a straight line which passes through the center of a mounting facility circle,and terminates at the circumference.CWFQ
Mounting Facility Circle Diameter:
5.750 inches
MRC:
The speed rating of a rotor,expressed in revolutions per minute.CWFX
Rotor Speed Rating In Rpm:
1260.0 single full load
MRC:
The amount of current for which an item is rated,expressed in amperes.CWGL
Current Rating In Amps:
103.000 single input
MRC:
Indicates the type of connection,rating sequence,and voltage rating at which the item is designed to operate,expressed in volts.CWGQ
Connection Type And Voltage Rating In Volts:
44.5 line to neutral single input
MRC:
An indication of the characteristic(s) of the shaft end.CWHZ
Shaft End Characteristic:
A9 first style single end and a13 second style single end
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
2 solder lug