TXT
묘사:
Fluid Pressure Regulating Valve
MRC:
The type of service with which the item is designed to be used.ACKL
Media For Which Designed:
Hydraulic fluid, mil-h-5606
MRC:
A narrative description of the type of end connection.ACKM
First End Connection Type:
Threaded internal boss
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the end.ACKN
First End Style Designator:
Gasket seal
MRC:
Designates the thread diameter,series/type,and number of threads per specific measurement scale.ACLJ
First End Thread Size And Series/type Designator:
1 5/8-12 unj
MRC:
A numeric-alpha designator indicating the pitch diameter tolerance and an external or internal thread.ACLK
First End Thread Class:
3b
MRC:
The direction of the thread when viewed axially. a right-hand thread winds in a clockwise direction while a left-hand thread winds in a counterclockwise direction.ACLL
First End Thread Direction:
Right-hand
MRC:
Indicates whether or not the second end is identical to the first end.ACLR
Second End Relationship With First End:
Identical
MRC:
The number of end connections included in the item.ADQZ
End Connection Quantity:
2
MRC:
A feature of the item of supply which must be specifically recorded when the reference number covers a range of items.ZZZY
Reference Number Differentiating Characteristics:
As differentiated by the source control dwg no.