TXT
묘사:
Capacitance-inductance-re Bridge
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
20.000 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
8.500 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
12.000 inches
MRC:
The value,or range of values,of root mean square potential for which the item is rated.ACYN
Ac Voltage Rating:
Between 115.0 volts and 230.0 volts
MRC:
The value,or range of values,of direct current potential for which the item is rated.ACYR
Dc Voltage Rating:
180.0 volts
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
60.0 hertz
MRC:
An indication of whether or not a facility/ies/ to accommodate a battery/ies/ is included.ALSF
Internal Battery Accommodation:
Not included
MRC:
The minimum to maximum limits of the capacitance scale.AQYN
Capacitance Scale Range:
+1.0/+100000.0 micro-microfarads
MRC:
The minimum to maximum limits of the capacitance scale.AQYN
Capacitance Scale Range:
+1.0 to 100000.0 micro-microfarads
MRC:
The minimum and maximum deviation from the exact capacitance reading at full scale deflection,expressed in percent.AQYP
Capacitance Scaleaccuracy Rating In Percent:
-2.0/+2.0
MRC:
The minimum and maximum deviation from the exact capacitance reading at full scale deflection,expressed in percent.AQYP
Capacitance Scaleaccuracy Rating In Percent:
-2.0 to 2.0
MRC:
The limits of the ratio of resistance to capacitive reactance,in percent.ARDZ
Dissipation Factor In Percent:
+0.002/+1.000
MRC:
The limits of the ratio of resistance to capacitive reactance,in percent.ARDZ
Dissipation Factor In Percent:
+0.002 to 1.000
MRC:
The minimum to maximum limits of the inductance scale.AREB
Inductance Scale Range:
+1.0/+100000000.0 microhenries
MRC:
The minimum to maximum limits of the inductance scale.AREB
Inductance Scale Range:
+1.0 to 100000000.0 microhenries
MRC:
The minimum and maximum deviation from the exact inductance reading at full scale deflection.AREC
Inductance Scaleaccuracy Rating In Percent:
-2.0/+2.0
MRC:
The minimum and maximum deviation from the exact inductance reading at full scale deflection.AREC
Inductance Scaleaccuracy Rating In Percent:
-2.0 to 2.0
MRC:
The minimum to maximum limits of the resistance scale.ARED
Resistance Scale Range:
+0.000000001/+1.000000000 megohms
MRC:
The minimum to maximum limits of the resistance scale.ARED
Resistance Scale Range:
+0.000000001 to 1.000000000 megohms
MRC:
The minimum and maximum deviation from the exact resistance reading at full scale deflection.AREE
Resistance Scaleaccuracy Rating In Percent:
-2.0/+2.0
MRC:
The minimum and maximum deviation from the exact resistance reading at full scale deflection.AREE
Resistance Scaleaccuracy Rating In Percent:
-2.0 to 2.0
MRC:
The type of indicator used to signify whether the item is in balance.AREH
Balance Indicator Type:
Galvanometer
MRC:
The number of alternating current phases.FAAZ
Phase:
Single