MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
Body Style:
Bushing mount
MRC:
A measurement of the longest dimension of a bushing,in distinction from width.ABXD
Bushing Length:
0.470 inches
MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
1.100 inches
MRC:
A measurement taken at right angles to the length of the body,in distinction from thickness.ADAT
Body Width:
0.670 inches
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the actuator.AFUQ
Actuator Style:
Round
MRC:
The length of a straight line which passes through the center of the actuator,and terminates at the circumference.AFUR
Actuator Diameter:
0.430 inches
Actuator Height:
1.180 inches
MRC:
The relationship between the actuator position and the actuator action /maintained or momentary/.AFUX
Actuator Position-action Relationship:
Up position maintained and down position maintained and center position maintained
MRC:
The relationship between the actuator position and the integral facility designed to prevent actuator movement.AFUY
Actuator Position-locking Relationship:
Up position no locking action and down position locked in and center position no locking action
MRC:
The hue or tint of the actuator.AFVA
Actuator Color:
White single actuator
MRC:
The maximum voltage rating at which the item is designed to operate in an alternating current and/or direct current circuit,expressed in volts.AFXE
Maximum Voltage Rating In Volts:
250.0 ac and 400.0 dc
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Uninclosed
MRC:
The means of attaching the item.AXGY
Mounting Method:
Threaded bushing
MRC:
The number of threads on the item per linear inch measured on a line parallel to the thread axis.CMLP
Thready Qty Per Inch (tpi):
32
MRC:
A designation that is used for the purpose of general identification of the thread.CQJX
Thread Size:
0.469 inches
MRC:
The designation that identifies the electrical configuration of a nonpile-up contact group including the number of switching poles or forms.CRLD
Nonpile-up Contact Arrangement:
4 pole, double throw, two positions momentary single switch unit
MRC:
The amount of current the contacts are rated to make or break at maximum rated voltage,with a specified load.CXQR
Contact Load Current Rating At Maximum Rated Voltage:
7.000 amperes resistive dc and 7.000 amperes inductive dc and 3.300 amperes motor dc and 2.000 amperes lamp dc and 7.000 amperes resistive ac and 7.000 amperes inductive ac and 3.300 amperes motor ac and 2.000 amperes lamp ac
MRC:
A designation distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.THSD
Thread Series Designator:
Uns
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
12 turret