부품 정보
P2 includes 6in. Of m22759/11-22-0 with connector ms25036-148 size no. 4
MRC:
The style designation indicating the configuration that most nearly corresponds to the cross-sectional shape of the item.AAGR
Cross Sectional Shape:
Round
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
E/i is an-ssq-12 (v)3 pal and an/ssq-124(v) 4 pal tactical exploitation systems
MRC:
Indicates the type of facility provided on the device for attaching to another item.AKRZ
Termination Type:
Connector receptacle all ends all conductors
MRC:
The number of electrical conductors included on the item.AMQN
Conductor Quantity:
2
MRC:
Indicates the type and number of accessory wires furnished with the item.AWTB
Accessory Wire Type And Quantity:
1 ground
MRC:
The number of strands per conductor.BLNZ
Strand Quantity Per Conductor:
7 all conductors
MRC:
The fabricated form of the conductor.CXCW
Conductor Form:
Stranded all conductors
MRC:
The designation used to describe the round stranded or round solid conductor size.CXDC
Round Conductor Size:
22 awg all conductors
MRC:
The american wire gage size of the individual strands of wire used in each stranded conductor.CXDG
Strand Awg Size Per Conductor:
30 all conductors
MRC:
The arrangement and number of arrangements of the conductors.CXDQ
Conductor Arrangement And Quantity:
4 singles
MRC:
The identifying reference number assigned to the terminal(s) by the manufacturer.CXGG
Terminal Manufacturer Identifying Reference Number:
M24308/2-1 2nd end all conductors
MRC:
The identifying reference number assigned to the terminal(s) by the manufacturer.CXGG
Terminal Manufacturer Identifying Reference Number:
M24308/2-3 1st end all conductors
MRC:
The five-position commercial and government entity code for the manufacturer of the terminal.CXGN
Terminal Commercial And Government Entity Code:
81439 all ends all conductors
MRC:
A measurement of the longest dimension of an individual conductor,in distinction from width.CXGW
Individual Conductor Length:
94.500 inches all ends all conductors and 96.500 inches all ends all conductors
MRC:
A characteristic of light that can be specified in terms of luminance,dominant wavelength,and purity.HUES
Color:
Black 1st position primary insulation first conductor
MRC:
A characteristic of light that can be specified in terms of luminance,dominant wavelength,and purity.HUES
Color:
Red 1st position primary insulation third conductor
MRC:
A characteristic of light that can be specified in terms of luminance,dominant wavelength,and purity.HUES
Color:
White 1st position primary insulation second conductor
MRC:
A characteristic of light that can be specified in terms of luminance,dominant wavelength,and purity.HUES
Color:
Green 1st position primary insulation fourth conductor
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Aluminum 2nd position shield foil cable and plastic polyester 2nd position shield foil cable
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Copper 3rd position shield braid, metallic cable
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Copper core conductor all conductors
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Plastic polytetrafluoroethylene 1st position primary insulation all conductors
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Plastic polytetrafluoroethylene 4th position jacket cable
MRC:
An indication of the precious material and its location in the item.PMLC
Precious Material And Location:
Contact surfaces gold and conductor surfaces silver
MRC:
Identification of the precious material contained in the item.PRMT
Precious Material:
Gold and silver
MRC:
The metallic,nonmetallic,and/or chemical properties with which the item is plated,dipped,and/or coated.the treatment is designed to protect the surface(s) and cannot be wiped off.SFTT
Surface Treatment:
Tin 3rd position shield braid, metallic cable
MRC:
The metallic,nonmetallic,and/or chemical properties with which the item is plated,dipped,and/or coated.the treatment is designed to protect the surface(s) and cannot be wiped off.SFTT
Surface Treatment:
Tin core conductor all conductors