MRC:
An indication that the level of probability that an item will operate without failure,at a specified rated capability,at a specified temperature,and for a specified period of time,has been established by testing random samples of production lot.AARG
Reliability Indicator:
Not established
MRC:
The temperature levels at which resistance ratings have been established,under zero power condition.AEJD
Tempurature Points For Resistance Readings At Zero Power:
104.4 degrees celsius 7th resistance-temperature point
MRC:
The temperature levels at which resistance ratings have been established,under zero power condition.AEJD
Tempurature Points For Resistance Readings At Zero Power:
126.7 degrees celsius 8th resistance-temperature point
MRC:
The temperature levels at which resistance ratings have been established,under zero power condition.AEJD
Tempurature Points For Resistance Readings At Zero Power:
37.8 degrees celsius 1st resistance-temperature point
MRC:
The temperature levels at which resistance ratings have been established,under zero power condition.AEJD
Tempurature Points For Resistance Readings At Zero Power:
48.9 degrees celsius 2nd resistance-temperature point
MRC:
The temperature levels at which resistance ratings have been established,under zero power condition.AEJD
Tempurature Points For Resistance Readings At Zero Power:
60.0 degrees celsius 3rd resistance-temperature point
MRC:
The temperature levels at which resistance ratings have been established,under zero power condition.AEJD
Tempurature Points For Resistance Readings At Zero Power:
71.1 degrees celsius 4th resistance-temperature point
MRC:
The temperature levels at which resistance ratings have been established,under zero power condition.AEJD
Tempurature Points For Resistance Readings At Zero Power:
82.2 degrees celsius 5th resistance-temperature point
MRC:
The temperature levels at which resistance ratings have been established,under zero power condition.AEJD
Tempurature Points For Resistance Readings At Zero Power:
93.3 degrees celsius 6th resistance-temperature point
MRC:
The resistance at a selected temperature,under zero power condition.AEJE
Zero Power Resistance At Specificationified Temp:
28.4 ohms 7th resistance-temperature point
MRC:
The resistance at a selected temperature,under zero power condition.AEJE
Zero Power Resistance At Specificationified Temp:
33.6 ohms 6th resistance-temperature point
MRC:
The resistance at a selected temperature,under zero power condition.AEJE
Zero Power Resistance At Specificationified Temp:
40.2 ohms 5th resistance-temperature point
MRC:
The resistance at a selected temperature,under zero power condition.AEJE
Zero Power Resistance At Specificationified Temp:
50.0 ohms 4th resistance-temperature point
MRC:
The resistance at a selected temperature,under zero power condition.AEJE
Zero Power Resistance At Specificationified Temp:
65.0 ohms 3rd resistance-temperature point
MRC:
The resistance at a selected temperature,under zero power condition.AEJE
Zero Power Resistance At Specificationified Temp:
120.1 ohms 1st resistance-temperature point
MRC:
The resistance at a selected temperature,under zero power condition.AEJE
Zero Power Resistance At Specificationified Temp:
20.5 ohms 8th resistance-temperature point
MRC:
The resistance at a selected temperature,under zero power condition.AEJE
Zero Power Resistance At Specificationified Temp:
88.8 ohms 2nd resistance-temperature point
MRC:
The limits of permissible variation in the electrical resistance value of an item at a selected temperature in percent.AEJF
Resistance Tolerance At A Specificationified Tempurature In Percent:
-15.0/+15.0 all resistance-temperature points
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Encapsulated
MRC:
The measured weight of an item unencumbered by packaging or packing material.PKWT
Unpackaged Unit Weight:
0.200 pounds