부품 정보
Frequency range 8.5 to 9.6 ghz
TXT
묘사:
Waveguide Assembly
MRC:
The style designation indicating the configuration that most nearly corresponds to the cross-sectional shape of the item.AAGR
Cross Sectional Shape:
Internal, rectangular external, rectangular
MRC:
The angular measurement by which one part/section of a rigid item deviates from a straight line projection of an adjacent part/section,expressed in degrees.ACJL
Bend Angle In Deg:
42.5 single bend e-plane
MRC:
The style designation indicating the configuration that most nearly corresponds to the construction of the tubing wall.AHRV
Tubing Wall Construction Style:
Corrugated single tubing segment
MRC:
Indicates the type of twist as characterized by the method or manner by which the rotation of the cross-sectional axes of the tubing is affected.AHRW
Tubing Twist Type:
Twistable single tubing segment
MRC:
The angle to which a rigid tubing has been intentionally rotated during manufacture or the maximum angle to which a twistable type tubing may be rotated,as measured in degrees of angular difference between the plane of a specific transverse dimension at one extremity of the tubing and the plane of the same dimension at the other extremity.AHRX
Tubing Twist Angle In Deg:
85.0 single tubing segment
MRC:
The number of flanges provided with the item.AHSF
Flange Quantity:
2
Flange Inside Width:
1.118 inches all flanges and 1.126 inches all flanges
Flange Inside Height:
0.493 inches all flanges and 0.501 inches all flanges
Flange Outside Width:
2.480 inches all flanges and 2.520 inches all flanges
Flange Outside Height:
1.730 inches all flanges and 1.770 inches all flanges
MRC:
A measurement between specified points on the flange,in distinction from height.AHTD
Flange Depth:
0.480 inches all flanges and 0.520 inches all flanges
MRC:
The length of a straight line which passes through the center of a flange connecting hole,and terminates at the circumference.AHTN
Flange Connecting Hole Diameter:
0.169 inches all flanges all connection facilities and 0.171 inches all flanges all connection facilities
MRC:
The ratio of the maximum to the minimum amplitude of pressure /voltage/ measured along the path of the waves.AHTW
Voltage Standing Wave Ratio:
1.20
MRC:
The difference in the amount of energy available before and after the insertion of an apparatus in a transmission system,expressed in decibels.AHTX
Insertion Loss In Decibels:
0.20
MRC:
The maximum pressure at which the item is rated for operation.CQGM
Maximum Operating Pressure:
15.0 pounds per square inch gage
Waveguide Outside Width:
Between 1.246 inches and 1.254 inches
Waveguide Inside Width:
Between 1.118 inches and 1.126 inches
Waveguide Inside Height:
Between 0.493 inches and 0.501 inches
Waveguide Outside Height:
Between 0.621 inches and 0.629 inches
MRC:
The type and number of facilities by which the flange is connected.CSQT
Flange Connecting Facility And Quantity:
8 unthreaded hole all flanges all connection facilities
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the flange.CTCJ
Flange Style:
Contact type all flanges
Waveguide Length:
12.000 inches
MRC:
Flexible,capable of being bent,turned or twisted,within limits,without breaking,or rigid,resisting change of form,inflexible.FLEX
Flexibility:
Flexible single tubing segment
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Copper alloy all tubing segment and flange
MRC:
An indication of the precious material and its location in the item.PMLC
Precious Material And Location:
Internal surfaces silver
MRC:
Identification of the precious material contained in the item.PRMT
Precious Material:
Silver
MRC:
The metallic,nonmetallic,and/or chemical properties with which the item is plated,dipped,and/or coated.the treatment is designed to protect the surface(s) and cannot be wiped off.SFTT
Surface Treatment:
Cadmium all tubing segment and flange outside surfaces and chromate all tubing segment and flange outside surfaces
MRC:
The metallic,nonmetallic,and/or chemical properties with which the item is plated,dipped,and/or coated.the treatment is designed to protect the surface(s) and cannot be wiped off.SFTT
Surface Treatment:
Silver all tubing segment and flange inside surfaces
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Straight type
MRC:
The justification for the assignment of a federal supply class /fsc/ to an item based on the classification of the next higher classifiable assembly.ZZZV
Fsc Application Data:
Antennas, waveguides, and related equip.