부품 번호 614ANALYZERWPROV.ANDREUSAB-

Sodium-potassium Analyzer

가격 및 가용성

이 NSN의 현재 가격 및 가용성에 대해 이 양식을 제출하십시오.
부품 번호:
양:
이메일 주소:
전화:
참조:
회사:
이름:

우리는 귀하의 정보를 누구에게도 공유하거나 판매하지 않습니다.
사생활 | 용어

All major credit cards accepted as well as gov. p-cards

이 제품의 과거 가격은 6097.507 and 7973.663 USD. 수량, 가용성, 상태, 리드 타임 및 품목 중단 가능성에 따라 최신 견적을 제공할 때까지 가격을 보장할 수 없습니다.

부품 번호
비무장화
수명
UOM
NIIN
부품 번호:
614analyzerwprov.andreusab-
비무장화:
No
수명:
24 mo.
측정 단위:
1 EA
NIIN:
013008711

부품 정보
Analyzer potassium and sodium ion selective:

NSN
국가 주식 번호:
6630-01-300-8711 6630013008711
TXT
묘사:
Sodium-potassium Analyzer
INC
INC
아이템 이름 코드:
38487
MRC:
A measurement from the bottom to the top of an object,in distinction from depth.ABRN
Height:
360.0 millimeters
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Ac
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
50.0 hertz or 60.0 hertz
MRC:
The name and number of parts supplied with the item which may be required for application.AKYD
Accessory Components And Quantity:
Pottasium electrodes, 1; sodium electrode, 1; reference electrode, 1; bottle of standard a, 2; bottle of standard b, 1; waste bottle, 1; bottle of reference filling solution, 1; bottle of test dye solution, 1; reference membrane assembly, 2; fluid path module, 1; bottle electrode rinse solution, 1; slide valve, 1; sample probe assembly, 1; reusable storage container, 1
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Digital display screen and integral printer and self-calibration
MRC:
The method by which an instrument performs the actual assay(s) of a sample/specimen.CYFV
Method Of Analysis:
Potentiometric/ion selective electrode
MRC:
Indicates the type of electrode(s) employed in the item to produce a specific ion assay of a sample/specimen.CYFX
Electrode Type:
Potassium/k+ and reference and sodium/na+
MRC:
The built in testing range for each type of test/assay that the analytical instrument is capable of performing.CYFY
Analysis Test/measurement Range:
Sodium 100-170 mmol/l in blood and 14-1400 mmol/l in undiluted urine; potassium 2-7 mmol/l in blood and 0.4-400 mmol/l in undiluted urine
MRC:
The amount,mass,volume,etc.,of a sample/specimen needed by the item to run a complete assay/test.CYFZ
Test Sample/specimen Size:
100 microliters of blood or 400 microliters of prediluted urine
MRC:
A means by which a sample/specimen is introduced into the analytical area of an item.CYGE
Err Default:
Err default
MRC:
Indicates the type of sample/specimen the item is capable of ascertaining qualitative and/or quantitative assay determinations.CYHM
Test Sample/specimen Type:
Whole blood, serum, plasma, and urine
MRC:
A measurement between specified points on an item, in distinction from height.DPTH
Depth:
230.0 millimeters
MRC:
The total electrical voltage.ELEC
Voltage In Volts:
120.0 or 230.0
MRC:
Those unusual or unique characteristics or qualities of an item not covered in the other requirements and which are determined to be essential for identification.FEAT
Special Features:
If the analyzer does not contain an integral printer, it shall be capable of interfacing w/a commercially available external printer
MRC:
A measurement of volume taken by multiplying the length by the width by the height of the unit of issue and rendered in cubic units.SUCB
Unit Of Issue Cube:
2.820 cubic feet
MRC:
The measured weight of the actual container(s) or supporting device(s) which is in direct contact with the item and its contents.SUWT
Unit Of Issue Weight:
29.00 pounds
MRC:
A measurement taken at right angles to the length of an item,in distinction from thickness.WDTH
Width:
260.0 millimeters

{lang[cimilar]} Sodium-potassium Analyzers

« Chemical Analysis Instruments {lang[catalog]}
지금 비교»
맑다 | 숨기다