MRC:
A measurement of the longest dimension of any object,in distinction from width.ABRY
Length:
16.125 inches
MRC:
The value,or range of values,of root mean square potential for which the item is rated.ACYN
Ac Voltage Rating:
Between 103.5 volts and 126.5 volts
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
Between 50.0 hertz and 1000.0 hertz
MRC:
The principal parts that are included in an assembled unit.AEAS
Major Components:
Test set, radar; case, test set
MRC:
The name assigned to the item by the joint electronics type designation system.AKWA
Joint Electronics Type Designation System Item Name:
Test set, radar
MRC:
The type number assigned to the item by the joint electronics type designation system.AKWB
Joint Electronics Type Designation System Item Type Number:
An/upm42paren
MRC:
The element,compound,or mixture of which the item is fabricated,excluding any surface treatment,and its location.ANNQ
Material And Location:
Aluminum carrying case
MRC:
An indication of the feature/s/ of the inclosure.ANPZ
Inclosure Feature:
Single item w/carrying case
MRC:
Indicates the type of test for which the item is designed.AQXY
Test Type For Which Designed:
Measure power and freq; display freq, freq spectrum of rf pulses; receiver recovery time, sensitivity, bandwidth, tr boxes, afc systems
MRC:
The testing functions such as range,sensitivity,output,and the like,for which the item is designed.AQXZ
Operating Test Capability:
Frequency range 23500 to 24500 mc, output m50 to m100 dbm, internal modulation fm or pulse, spectrum analyzer, pulse width range 0.1 to 3 microseconds, sweep speed 10 to 30 hz, synchroscope sweep speeds 5, 15 and 40 microseconds, deflection sensitivi type 60 volts per in.
MRC:
The number of alternating current phases.FAAZ
Phase:
Single
MRC:
A measurement from the bottom to the top of an object,in distinction from depth.HGTH
Height:
15.000 inches