묘사:
Refrigeration Compressor
MRC:
The media the machine is designed to compress.AAXK
Gas For Which Designed:
Refrigerant r-12
MRC:
The rated capacity of gas delivered by the last stage of compression.AAXL
Discharge Flow Rate:
Not rated
MRC:
The gage pressure of gas delivered by the last stage of compression. referred to as condensing pressure for refrigeration compressors.AAXM
Discharge Pressure:
126.600 pounds per square inch gage
MRC:
The design of the system necessary to maintain the required operating temperature of an item and discharge temperature of the compressed gases.AAXP
Cooling System Design:
Single
MRC:
The cooling medium used to maintain the required operating temperature of the compressor.AAXR
Compressor Cooling Medium:
Refrigerant
MRC:
The method by which a no load condition is obtained for starting the item.AAXV
Unloader Type:
Automatic
MRC:
The power required to start and operate the item at the actual rated capacity,including all accessories.AAXW
Brake Horsepower Required:
38.100
MRC:
The reciprocating compressor design as determined by the mechanical action by which compression takes place in the cylinder/s/ of the compressor.AAXY
Reciprocating Compressor Design:
Single acting
MRC:
The number of cylinders incorporated in the item.AAXZ
Cylinder Quantity:
6
MRC:
The style designation indicating the configuration that most nearly corresponds to the angular arrangement of the cylinders.AAYA
Cylinder Arrangement Style:
"w" design
MRC:
The number of stages incorporated in the item.AAYD
Stage Quantity:
1
MRC:
The refrigeration capacity of the item as rated by industry,expressed in tons per hour.AAYE
Refrigeration Flow Rate In Tons Per Hour:
35.0
MRC:
The pressure of the gas after it has passed through the evaporator and prior to its compression within the item.AAYF
Suction Pressure:
34.0 pounds per square inch
MRC:
The speed of the compressor required to produce its rated capacity,expressed in revolutions per minute.AAYS
Compressor Speed At Rated Capacity In Rpm:
1750.0
MRC:
The number of intake connections included on the item.AAYT
Intake Connection Quantity:
1
MRC:
Indicates the type of intake connection included on the item.AAYU
Intake Connection Type:
Square flange
MRC:
The number of discharge connections included on the item.AAYV
Discharge Connection Quantity:
1
MRC:
Indicates the type of discharge connection included on the item.AAYW
Discharge Connection Type:
Square flange
MRC:
Indicates the type of connection between the prime mover and the shaft.AAYX
Drive Connection Type:
Flexible coupled
MRC:
The degree of heat or cold as applied to the function of the item.CSFH
Tempurature Rating Per Function:
105.0 degrees fahrenheit discharge and 36.0 degrees fahrenheit suction
MRC:
The brake power required to start and operate the item including all accessories at the actual rated capacity,expressed in unit of power.CXNT
Brake Power Required:
38.100 horsepower