부품 정보
Media for which designed: methyl chloride, gas refrigerant 12, sulphur diodioxide, gaseous
MRC:
The basic material of which the body is fabricated.AAFZ
Body Material:
Brass
MRC:
Consists of plating,dip,and/or coating that cannot be wiped off. plating and/or coating is any chemical and/or metallic additive,electrochemical,or mild mechanical process which protects the outside surface.AAJP
Outside Surface Treatment:
Any acceptable
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
Body Style:
Straight thru
MRC:
A value which expresses the degree of heat or cold as applied to the operation,or limitation of operation,of an item.ABJH
Tempurature Rating:
Not rated
MRC:
The type of service with which the item is designed to be used.ACKL
Media For Which Designed:
Methyl chloride, gas err-100 err-100
MRC:
The type of service with which the item is designed to be used.ACKL
Media For Which Designed:
Refrigerant 12 err-100 err-100
MRC:
The type of service with which the item is designed to be used.ACKL
Media For Which Designed:
Sulphur dioxide, gaseous err-100 err-100
MRC:
A narrative description of the type of end connection.ACKM
First End Connection Type:
Threaded external tube
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the end.ACKN
First End Style Designator:
Flared
MRC:
The length of a straight line which passes through the center of the accommodated tube,and terminates at the outside circumference.ACLH
First End Outside Diameter Tube Accommodated:
0.375 inches
MRC:
Designates the thread diameter,series/type,and number of threads per specific measurement scale.ACLJ
First End Thread Size And Series/type Designator:
0.625-18 unf
MRC:
A numeric-alpha designator indicating the pitch diameter tolerance and an external or internal thread.ACLK
First End Thread Class:
2a
MRC:
The direction of the thread when viewed axially. a right-hand thread winds in a clockwise direction while a left-hand thread winds in a counterclockwise direction.ACLL
First End Thread Direction:
Right-hand
MRC:
Indicates whether or not the second end is identical to the first end.ACLR
Second End Relationship With First End:
Not identical
MRC:
A narrative description of the type of end connection.ACLS
Second End Connection Type:
Threaded internal pipe
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the end.ACLT
Second End Style Designator:
Plain
MRC:
The industrial designation or term used to define the nominal diameter of the pipe the end will accommodate.ACMN
Second End Pipe Size Accommodated:
0.250 inches
MRC:
Designates the thread diameter,series/type,and number of threads per specific measurement scale.ACMQ
Second End Thread Size And Series/type Designator:
0.250-18 npt
MRC:
The direction of the thread when viewed axially. a right-hand thread winds in a clockwise direction while a left-hand thread winds in a counterclockwise direction.ACMS
Second End Thread Direction:
Right-hand
MRC:
The angle of the end surface upon which the mated surface seats,expressed in degrees.ACTE
First End Seat Angle In Deg:
45.0
MRC:
The part that controls the flow through the item.ADQU
Flow Control Device:
Any acceptable
MRC:
The number of end connections included in the item.ADQZ
End Connection Quantity:
2
MRC:
The minimum to maximum pressures at which the item may be adjusted.ADSW
Adjustable Pressure Range:
+0.1/+35.0 pounds per square inch
MRC:
The minimum to maximum pressures at which the item may be adjusted.ADSW
Adjustable Pressure Range:
+0.1 to 35.0 pounds per square inch
MRC:
Indicates the type of control by which the valve is expanded.AFKK
Valve Expansion Control Type:
Pressure
MRC:
An indication of whether or not a device is included that throttles or stops the flow of liquid,gas,and the like,through the valve when evaporator suction pressure reaches the maximum pressure setting.AFKM
Valve Pressure Limiting Device:
Not included
MRC:
Indicates whether the equalizer location is internal,external,or both.AFKU
Valve Equalizer Location:
Internal
MRC:
The capacity of the item as rated by industry,expressed in british thermal units /btu/ of refrigeration per hour.AGUB
Refrigeration Capacity In Btu Per Hour:
25.2