TXT
묘사:
Permanent Magnet Loudspeaker
MRC:
The number of terminals for providing electrical connection to the item.AARA
Terminal Quantity:
2
MRC:
Indicates the type of terminals for providing electrical connection to the item.AARB
Terminal Type:
Tab, solder lug
MRC:
An overall measurement between specified points of an item,in distinction from height.ABFY
Overall Depth:
3.380 inches
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
4.720 inches
MRC:
The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the length.ABKQ
Center To Center Distance Between Mounting Facilities Parallel To Length:
3.750 inches
MRC:
The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the width.ABKR
Center To Center Distance Between Mounting Facilities Parallel To Width:
3.750 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
4.690 inches
MRC:
The length of a straight line which passes through the center of a mounting hole,and terminates at the circumference.ABTB
Mounting Hole Diameter:
0.200 inches
MRC:
The minimum and maximum frequencies to which the item will respond,expressed in hertz.AFYW
Frequency Response Range In Hertz:
+300.0/+7000.0
MRC:
The amount of electrical energy that can be dissipated.AJDB
Power Rating:
5.00 watts normal and 7.00 watts peak
MRC:
A measurement of the longest dimension of the transducer,in distinction from width.AKNR
Transducer Length:
2.750 inches
MRC:
A measurement taken at right angles to the length of the transducer,in distinction from thickness.AKNS
Transducer Width:
1.750 inches
MRC:
The number of mounting facilities provided.AKPV
Mounting Facility Quantity:
4
MRC:
Indicates the type of device that converts energy from one form to another.AKVS
Transducer Type:
Diaphragm
MRC:
Indicates the designed use of the item.ALBY
Usage Design:
Indoor
MRC:
The installation for which the item is designed.AMQY
Installation Design:
Nonportable
MRC:
The total opposition /resistive and reactive/ which the item offers to the flow of alternating current,expressed in ohms.AWZH
Impedance Rating In Ohms:
8.0 voice coil
MRC:
The means of attaching the item.AXGY
Mounting Method:
Unthreaded hole
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Square
MRC:
The specification,standard,drawing,or similar instrument that specifies environmental and performance requirements or test conditions under which an item is tested and establishes acceptable limits within which the item must conform identified by an alphabetic and/or numeric reference number. includes the commercial and government entity (cage) code of the entity controlling the instrument.TEST
Test Data Document:
81349-mil-l-10911 specification (includes engineering type bulletins, brochures, etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "", etc.).