부품 정보
Microcircuit, hybrid, memory, flash ereasable/programmable read only memory, 512k x 32 bit
TXT
묘사:
Hybrid Microcircuit
MRC:
The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
Operating Tempurature Range:
-55.0/+125.0 degrees celsius
MRC:
The minimum and maximum temperatures at which an item can be stored without detrimental effect.AFJQ
Storage Tempurature Range:
-65.0/+150.0 degrees celsius
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Erasable and programmable and hybrid
MRC:
Indicates the physical configuration of the inclosure.CQSZ
Inclosure Configuration:
Single-in-line
MRC:
The basic purpose and number of functions of the device,modified by its intended use.CSSL
Design Function And Quantity:
1 memory
MRC:
The metallic,nonmetallic,and/or chemical properties with which the item is plated,dipped,and/or coated. the treatment is designed to protect the terminal surface(s) and cannot be wiped off.CWSG
Terminal Surface Treatment:
Solder
MRC:
The value of the voltage applied and type of specific electrical characteristic for which the item is designed.CZEN
Voltage Rating And Type Per Characteristic:
-2.0 volts input and 7.0 volts input
MRC:
Indicates the type of hybrid technology used in the item.CZES
Hybrid Technology Type:
Monolithic
MRC:
Those unusual or unique characteristics or qualities of an item not covered in the other requirements and which are determined to be essential for identification.FEAT
Special Features:
Co-fired ceramic, 1.075, hex-in-line, single cavity, with standoffs, circuit function - eprom flash, 512k x 32 bit, access time - 90ns
MRC:
The specification,standard,drawing,or similar instrument that specifies environmental and performance requirements or test conditions under which an item is tested and establishes acceptable limits within which the item must conform identified by an alphabetic and/or numeric reference number. includes the commercial and government entity (cage) code of the entity controlling the instrument.TEST
Test Data Document:
96906-mil-std-883 standard (includes industry or association standards, individual manufactureer standards, etc.).
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
66 case