TXT
묘사:
Thermostatic Switch
MRC:
A numeric-alpha designator indicating the pitch diameter tolerance and an external or internal thread.AAJD
Thread Class:
2a single threaded bushing
MRC:
The specific commercial rating which classes the item as to what degree the item will withstand environmental elements and/or hazardous locations.ABFE
Hazardous Locations/environmental Protection:
Humidity resistant and salt spray resistant and vibration resistant and waterproof
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
3.770 inches
MRC:
The length of a straight line which passes through the center of the body,and terminates at the circumference.ABPM
Body Diameter:
0.650 inches
MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
1.440 inches
MRC:
Indicates the type of sensor or transducer used in the item to convert temperature changes to switch actuating force.AKBY
Tempurature Sensing Element Type:
Internal sensor
MRC:
The temperature at which the item operates.AWTN
Operating Tempurature Rating:
Between -65.0 degrees fahrenheit and 390.0 degrees fahrenheit
MRC:
The means of attaching the item.AXGY
Mounting Method:
Threaded bushing
MRC:
An indication of whether the initial action of the contacts occurs as the result of an increase or decrease in stimulus.CQGB
Contact Action Stimulus:
Increase
MRC:
A designation that is used for the purpose of general identification of the thread.CQJX
Thread Size:
0.750 inches single threaded bushing
MRC:
The designation that identifies the electrical configuration of a nonpile-up contact group including the number of switching poles or forms.CRLD
Nonpile-up Contact Arrangement:
1 pole, single throw, normally closed, momentary action
MRC:
Indicates the type of terminal for providing electrical connection to the item.CSCF
Terminal Type:
Quick disconnect, male
MRC:
The amount of current that the contacts are rated to make or break with a specified load.CTHF
Contact Load Current Rating:
1.0 amperes resistive load single voltage
MRC:
The adjustability of the contact.CTYC
Contact Adjustability:
Actuation point not adjustable
MRC:
The rating of the stimulus required to actuate and/or deactuate the contact(s).CTYX
Contact Stimulus Rating:
260.00 actuation point degrees fahrenheit
MRC:
The voltage for which the contact(s) is rated at sea level or at a specified altitude,expressed in volts.CTZB
Contact Voltage Rating In Volts:
28.0 dc at sea level single voltage
MRC:
The type of media for which the item is designed.MEDA
Media For Which Designed:
Gas or liquid
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Cylindrical w/flange
MRC:
A designation distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.THSD
Thread Series Designator:
Unf single threaded bushing