부품 정보
High power; function: dummy load, rf, high power; reference data: at5, ti-6340.8, instruction book, arsr-3 system, part ii, vol 9, sec 8, pg 8-3
TXT
묘사:
Electrical Dummy Load
MRC:
The amount of coolant necessary to maintain the required operating temperature of the item.AAXT
Cooling System Coolant Flow Rate:
2.0 gallons per minute
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
31.810 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
10.250 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
7.000 inches
MRC:
A measurement taken at right angles to the length of the body,in distinction from thickness.ADAT
Body Width:
10.250 inches
MRC:
A measurement from the bottom to the top of the body,in distinction from depth.ADAU
Body Height:
7.000 inches
MRC:
The range of complete cyclic changes,per unit of time,for which an item is rated.AFGQ
Frequency Range Rating:
+1.250/+1.350 gigahertz
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
Arsr-3, fa9200
MRC:
The ratio of the maximum to the minimum amplitude of pressure /voltage/ measured along the path of the waves.AHTW
Voltage Standing Wave Ratio:
1.10
MRC:
The amount of electrical energy that can be dissipated.AJDB
Power Rating:
6.500 megawatts peak and 8.000 kilowatts average
MRC:
The minimum and maximum values of the frequency range in which the voltage standing wave ratio is specified.AKNK
Voltage Standing Wave Ratio Frequency Range:
+1.250/+1.350 gigahertz
MRC:
Indicates the type of facility provided on the device for attaching to another item.AKRZ
Termination Type:
Waveguide flange
MRC:
The alphabetical characters and numerals which identify the specific waveguide flange type.AKSA
Waveguide Flange Designation:
Ug418a/u
MRC:
The location of the threads on the intake connection.AKSC
Intake Connection Thread Location:
Internal
MRC:
The location of the threads on a discharge connection.AKSD
Discharge Connection Thread Location:
Internal
MRC:
The position in which the item is designed to operate.ARNH
Operating Position:
Horizontal
MRC:
The nominal exerted outward force,per unit of area,for which the item is designed.AWNC
Internal Operating Pressure:
15.0 pounds per square inch gage
MRC:
The nominal outward force,per unit of area,of the coolant chamber.AWNJ
Coolant Chamber Pressure:
100.0 pounds per square inch gage
MRC:
The means of cooling used to maintain the required operating temperature of the item.BFMF
Cooling Method:
Forced liquid
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Waveguide mounted