MRC:
The primary application for which the item is designed.AAFS
Application Design:
Transmission line
MRC:
The basic material of which the body is fabricated.AAFZ
Body Material:
Steel, corrosion resisting
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
Body Style:
Err-090
MRC:
Consists of plating,dip,and/or coating that cannot be wiped off. plating and/or coating is any chemical and/or metallic additive,electrochemical,or mild mechanical process which protects a body surface.ABEM
Body Surface Treatment:
Passivated, qq-p-35
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
0.860 inches
MRC:
A measurement of the longest straight line across a circular cross-sectional plane.ADAV
Overall Diameter:
Between 0.270 inches and 0.290 inches
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
An/alq-131 pod
MRC:
The ratio of the maximum to the minimum amplitude of pressure /voltage/ measured along the path of the waves.AHTW
Voltage Standing Wave Ratio:
1.12 and 1.20
MRC:
The total opposition (resistive and reactive) which the item offers to the admittance of an entering flow of alternating current,expressed in ohms.AHTY
Input Impedance Rating In Ohms:
50.0
MRC:
The total opposition /resistive and reactive/ which the output of the item provides to match,for maximum transfer of energy,the input impedance of another item,expressed in ohms.AHTZ
Output Impedance Rating In Ohms:
50.0
MRC:
A letter or group of letters used to designate the particular coaxial connector series.AHUC
Coaxial Connector Series Designation:
Sma
MRC:
The decrease in the strength of the radio frequency signals,expressed in decibels.AJDK
Rf Signal Attenuation In Decibels:
4.0
MRC:
The minimum and maximum values of the frequency range in which the voltage standing wave ratio is specified.AKNK
Voltage Standing Wave Ratio Frequency Range:
+2.0/+18.0 gigahertz
MRC:
Indicates the type and number of terminal(s) for providing electrical connection.BBHS
Terminal Type And Quantity:
1 connector and 1 ferrule
MRC:
The minimum and maximum cyclic changes,per unit of time,for which an item is rated.BNGR
Frequency Range:
Between 2.000 gigahertz and 18.000 gigahertz