부품 정보
Inductor at mounting end
TXT
묘사:
Radio Frequency Interfere Filter
MRC:
The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
Operating Tempurature Range:
-55.0/+125.0 degrees celsius
MRC:
The numeric value indicating the average life expectancy for which the item is rated,expressed in hours.AFSV
Average Life Rating In Hours:
1000.0
MRC:
The total opposition per function,presented by a source of energy to the input terminals of an item.AHAQ
Source Impedance Rating Per Function:
50.0 ohms blank
MRC:
The level of electrical flow,per function,for which the item is designed to operate,expressed in ampers.AHBC
Operating Current Rating Per Function In Amps:
10.0 blank
MRC:
The greatest amount of voltage loss per function,resulting from the devices inherent opposition to the flow of electrical current.AHBE
Maximum Voltage Drop Per Function:
100.0 millivolts dc blank
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Encased
MRC:
Indicates the functional type and number of terminals providing electrical connection to the item.CQDW
Functional Terminal Type And Quantity:
1 turret input 1st function
MRC:
Indicates the functional type and number of terminals providing electrical connection to the item.CQDW
Functional Terminal Type And Quantity:
1 wire lead output 2nd function
MRC:
The level of electrical potential and type of current,per function,for which the item is designed.CQGC
Operating Voltage Rating And Type Per Function:
100.0 volts dc blank