MRC:
The name and number of parts supplied with the item which may be required for application.AKYD
Accessory Components And Quantity:
Troop entry door with secure combination/cipher lock, 1; rear escape hatch with openings for ecu ducts, 1; 36k btu ecu's, 2; 100a input for critical and non critical power circuits, 2; breaker panels (custom designed main and deployable panel/receptacle box for critical power distribution to equipment racks), 2; vestibule with canvas door to protect personnel access door, 1; alluminum powder coated cableway to prohibit communication interferance, 1; opening for custom interface panel in ecu wall, 1
MRC:
Those unusual or unique characteristics or qualities of an item not covered in the other requirements and which are determined to be essential for identification.FEAT
Special Features:
Color is desert tan; also includes high speed mobility wheel set, adapter set and sling chains; slide in/slide out 42, 000 btu ecu; led lighting with blue led's with variable lighting dimming controls; outlets are included on the interior expandable panels; cable trays for communications wiring separate from the panduit used for electrical wiring on the roof panel; the 100 amp circuits (tw0) are separate such that one circuit is for critical equipment and the second circuit is for non critical equipment; retracted width is 8.000 feet; door quantity is 2; window quantity is 8; retracted length is 14.833 feet; specified use design is for communications purpose