MRC:
A measurement of the extent of threads,including incomplete threads,along a line parallel to the longitudinal axis.AASA
Thread Length:
0.437 inches single mounting facility
MRC:
The specific commercial rating which classes the item as to what degree the item will withstand environmental elements and/or hazardous locations.ABFE
Hazardous Locations/environmental Protection:
Explosion proof
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
2.275 inches
First Flat Length:
0.250 inches single actuator
Flat Height:
0.219 inches single actuator
MRC:
The length of a straight line which passes through the center of a shaft,and terminates at the circumference.ABWV
Shaft Diameter:
0.250 inches single actuator
MRC:
A measurement of the longest dimension of the shaft,in distinction from width.ABXF
Shaft Length:
0.974 inches single actuator
MRC:
A measurement of the longest straight line across a circular cross-sectional plane.ADAV
Overall Diameter:
1.124 inches
MRC:
The linear measurement of the distance from the actuator centerline to the centerline of the nonturn device.AEFP
Nonturn Device Radius:
0.375 inches at 3: 00 o'clock
MRC:
The number of individual sections included in the item.AFBH
Individual Section Quantity:
2
MRC:
Indicates the type of device used to prevent physical movement of the item on its mounting surface.AFDC
Nonturn Device Type:
Tab at 3: 00 o'clock
MRC:
The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
Operating Tempurature Range:
-65.0/+125.0 degrees celsius
MRC:
The general configuration of the contacts of a switch that describes its basic switching structure.AJZE
Switch Contact Basic Design:
Nonpile-up symmetrical
MRC:
The number of poles included in the item.AKPX
Pole Quantity:
2 each section front
MRC:
The number of positions to which the item may be actuated to energize electrical circuits.AKPY
Throw Quantity:
3 each section rear
MRC:
The means of attaching the item.AXGY
Mounting Method:
Threaded bushing single mounting facility
MRC:
A designation that is used for the purpose of general identification of the thread.CQJX
Thread Size:
0.375 inches single mounting facility
MRC:
The angular distance of the shaft flat or slot from the point of reference.CQRQ
Shaft Flat/slot Angular Location:
216.0 degrees from nonturn device single actuator
MRC:
Indicates the number of connections on a rotor segment that are front to rear surface connected.CQTH
Rotor Through Connection Quantity:
2 each section
MRC:
The number of positions to which the switch actuator may be indexed.CRJH
Switch Actuator Indexing Position Quantity:
3 single actuator
MRC:
Indicates the type of shaft included on the item.CRSJ
Shaft Type:
Round, flatted single actuator
MRC:
Indicates the type of terminal for providing electrical connection to the item.CSCF
Terminal Type:
Tab, solder lug
MRC:
An indication of the switching action by the contacts of the item.CSHW
Contact Switching Action:
Makes before breaks each section rear
MRC:
The increments of angular rotation that the switch actuator moves between adjacent index positions.CSLC
Switch Actuator Positioning Increment:
36.0 degrees single actuator
MRC:
The minimum and maximum amount of turning force required to rotate an actuator through the detent positions.CSMW
Detent Rotational Torque Range:
+0.500/+3.000 inch-pounds single actuator
MRC:
Indicates the type of device included in the switch to limit the angular rotation of its actuator.CTDN
Switch Actuator Stop Device Type:
Fixed stop single actuator
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Tap, circular, bushing mount
MRC:
A designation distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.THSD
Thread Series Designator:
Unef single mounting facility