TXT
				
				
					묘사:
				
				
					S Electrical Insulation Sleeving				
			 
			
										
					
						MRC:
						The maximum voltage the insulating materials of the item will withstand without resulting in disruptive discharge or deterioration,expressed in volts.AAPB
					 
					
						Dielectric Withstanding Voltage In Volts:
					
					
						200.0					
				 
							
					
						MRC:
						An indication that the level of probability that an item will operate without failure,at a specified rated capability,at a specified temperature,and for a specified period of time,has been established by testing random samples of production lot.AARG
					 
					
						Reliability Indicator:
					
					
						Not established					
				 
							
					
						MRC:
						A value which expresses the degree of heat or cold as applied to the operation,or limitation of operation,of an item.ABJH
					 
					
						Tempurature Rating:
					
					
						-55.0 degrees celsius and 150.0 degrees celsius					
				 
							
					
						MRC:
						The environmental elements or conditions that an item is designed or protected to resist or withstand satisfactorily.ADZC
					 
					
						Environmental Protection:
					
					
						Any acceptable					
				 
							
					
					
						Main Body Inside Diameter:
					
					
						0.740 inches  after unrestricted recovery					
				 
							
					
					
						Main Body Inside Diameter:
					
					
						1.520 inches  as supplied					
				 
							
					
					
						First Branch Inside Diameter:
					
					
						0.380 inches  after unrestricted recovery					
				 
							
					
					
						First Branch Inside Diameter:
					
					
						0.760 inches  as supplied					
				 
							
					
					
						Second Branch Inside Diameter:
					
					
						0.380 inches  after unrestricted recovery					
				 
							
					
					
						Second Branch Inside Diameter:
					
					
						0.760 inches  as supplied					
				 
							
					
					
						Third Branch Inside Diameter:
					
					
						0.380 inches  after unrestricted recovery					
				 
							
					
					
						Third Branch Inside Diameter:
					
					
						0.760 inches  as supplied					
				 
							
					
					
						Distance From Intersecting Centerline Of Main Body To End Of First Branch:
					
					
						2.900 inches  after unrestricted recovery					
				 
							
					
					
						Main Body Wall Thickness:
					
					
						0.120 inches  after unrestricted recovery					
				 
							
					
					
						First Branch Wall Thickness:
					
					
						0.070 inches  after unrestricted recovery					
				 
							
					
					
						Second Branch Wall Thickness:
					
					
						0.070 inches  after unrestricted recovery					
				 
							
					
					
						Third Branch Wall Thickness:
					
					
						0.070 inches  after unrestricted recovery					
				 
							
					
					
						Distance From Edge Of Main Body To Intersecting Centerlines:
					
					
						2.420 inches  after unrestricted recovery					
				 
							
					
					
						Main Bodylength:
					
					
						5.320 inches  after unrestricted recovery					
				 
							
					
					
						Angle Between Main Body And First Branch Centerlines In Deg:
					
					
						10.0  as supplied					
				 
							
					
					
						Angle Between Main Body And First Branch Centerlines In Deg:
					
					
						30.0  after unrestricted recovery					
				 
							
					
						MRC:
						The maximum rated load in tension applied in a longitudinal direction,per unit of cross-sectional area,that the material can withstand without rupture.CQBC
					 
					
						Min. Tensile Strength (psi):
					
					
						1500 pounds per square inch					
				 
							
					
						MRC:
						Flexible,capable of being bent,turned or twisted,within limits,without breaking,or rigid,resisting change of form,inflexible.FLEX
					 
					
						Flexibility:
					
					
						Flexible					
				 
							
					
						MRC:
						A characteristic of light that can be specified in terms of luminance,dominant wavelength,and purity.HUES
					 
					
						Color:
					
					
						Black					
				 
							
					
						MRC:
						The element,compound,or mixture of which an item is fabricated,excluding any surface treatment.MATL
					 
					
						Material:
					
					
						Rubber,  chloroprene					
				 
							
					
						MRC:
						The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
					 
					
						Material:
					
					
						Rubber chloroprene class cr					
				 
							
					
						MRC:
						The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
					 
					
						Style Designator:
					
					
						Transition-1 to 3 cables