MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
8.010 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
5.040 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
5.250 inches
MRC:
The relationship of the electrical power source to the item.AKWC
Electrical Power Source Relationship:
Operating
MRC:
The number of input alternating current phase(s).ANPM
Input Phase:
Single single operating power rqmt
MRC:
The input value/s/,or range of values,for which the item is rated.APNX
Input Voltage Rating:
115.0 ac volts single operating power rqmt
MRC:
The output value/s/,or range of values,for which the item is rated.APPA
Output Voltage Rating:
24.0 dc volts 5th power output
MRC:
The output value/s/,or range of values,for which the item is rated.APPA
Output Voltage Rating:
24.0 dc volts 7th power output
MRC:
The output value/s/,or range of values,for which the item is rated.APPA
Output Voltage Rating:
-24.0 dc volts 6th power output
MRC:
The output value/s/,or range of values,for which the item is rated.APPA
Output Voltage Rating:
-24.0 dc volts 8th power output
MRC:
The output value/s/,or range of values,for which the item is rated.APPA
Output Voltage Rating:
-50.0 dc volts 4th power output
MRC:
The output value/s/,or range of values,for which the item is rated.APPA
Output Voltage Rating:
-72.0 dc volts 2nd power output
MRC:
The output value/s/,or range of values,for which the item is rated.APPA
Output Voltage Rating:
50.0 dc volts 3rd power output
MRC:
The output value/s/,or range of values,for which the item is rated.APPA
Output Voltage Rating:
72.0 dc volts 1st power output
MRC:
The number of complete cyclic changes,per unit of time,for which the input is rated.APTQ
Input Frequency Rating:
400.0 hertz single operating power rqmt
MRC:
The ambient temperature range at which the item is designed to operate.AYNH
Operating Ambient Tempurature Range:
+0.1/+71.0 degrees celsius
MRC:
The output current rating at which the item is designed to operate.CWGH
Output Current Rating:
0.050 dc amperes 5th power output
MRC:
The output current rating at which the item is designed to operate.CWGH
Output Current Rating:
0.070 dc amperes 3rd power output
MRC:
The output current rating at which the item is designed to operate.CWGH
Output Current Rating:
0.500 dc amperes 7th power output
MRC:
The output current rating at which the item is designed to operate.CWGH
Output Current Rating:
-0.040 dc amperes 2nd power output
MRC:
The output current rating at which the item is designed to operate.CWGH
Output Current Rating:
-0.050 dc amperes 6th power output
MRC:
The output current rating at which the item is designed to operate.CWGH
Output Current Rating:
-0.070 dc amperes 4th power output
MRC:
The output current rating at which the item is designed to operate.CWGH
Output Current Rating:
-0.500 dc amperes 8th power output
MRC:
The output current rating at which the item is designed to operate.CWGH
Output Current Rating:
0.040 dc amperes 1st power output
MRC:
An indication of whether current or voltage or both are controlled,stabilized,or limited to obtain the required output power characteristics.CWGW
Power Supply Output Current/voltage Characteristics:
Constant current multiple power outputs w/identical ratings and constant voltage multiple power outputs w/identical ratings
MRC:
The number of electrical output connections on the item.CWHF
Output Connection Quantity:
1 multiple power outputs w/identical ratings
MRC:
Indicates the type of electrical output connection.CWHJ
Output Connection Type:
Receptacle, electrical multiple power outputs w/identical ratings
MRC:
Indicates the type of electrical input connection.CWHQ
Input Connection Type:
Terminal strip single operating power rqmt
MRC:
The number of electrical input connections on the item.CWHT
Input Connection Quantity:
1 single operating power rqmt
MRC:
The time required for a power supply(ies) to reach the full operating potential for which it is rated,expressed in minutes.CWKM
Warm Up Time In Minutes:
1