TXT
묘사:
El Engine Starter Relay-solenoid
MRC:
A measurement taken at right angles to the length of the mounting slot,in distinction from thickness.ABTD
Mounting Slot Width:
0.281 inches
MRC:
A measurement of the longest dimension of the mounting slot,in distinction from width.ABVG
Mounting Slot Length:
0.500 inches
MRC:
An indication of whether or not an item is capable of operation while submerged.AHZV
Submersibility:
Nonsubmersible
MRC:
The distance between the mounting facilities.ARKQ
Mounting Facility Spacing:
2.204 in. C to c
MRC:
The nominal value(s) of potential for which the item is rated.AWYG
Voltage Rating:
12.0 volts
MRC:
The voltage rating at which the item will close.AWZB
Closing Voltage Rating:
8.6 volts
MRC:
The voltage rating at which the item will open.AXAY
Opening Voltage Rating:
3.5 volts
MRC:
The amount of current required to maintain operation of the item.AXBA
Hold-in Current:
2.1 amperes
MRC:
An indication of whether or not the item includes provisions for manually closing the contacts.AXCC
Contact Manual Closing Provision:
Included
MRC:
The number of control terminals provided.AXCD
Control Terminal Quantity:
3
MRC:
Indicates the type of control terminal/s/ provided.AXCE
Control Terminal Type:
Threaded stud
MRC:
An indication of whether or not a grounded control terminal is included.AXCF
Grounded Control Terminal:
Included
MRC:
Indicates the type and number of facilities by which the item is mounted.AXHR
Mounting Facility Type And Quantity:
2 slot