MRC:
The element,compound,or mixture of which the inclosure is fabricated,excluding any surface treatment.ABBH
Inclosure Material:
Steel
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
5.750 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
4.250 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
4.250 inches
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Ac
MRC:
Indicates the type of switch included in the item.AEEA
Switch Type:
Rotary
MRC:
The pattern or arrangement that describes the mounting configuration of the item.ALGC
Mounting Configuration:
Four 9/32 in. Diameter mtg holes on 3.25 in. By 3.25 centers
MRC:
Indicates the type of relay/s/ provided.APCL
Relay Type:
Armature
MRC:
Indicates the type of current used with the contact/s/.APFX
Contact Current Type:
Ac
MRC:
The maximum voltage rating at which the item is designed to operate,expressed in volts.APFY
Maximum Voltage Rating In Volts:
115.000
MRC:
The amount of current at maximum rated voltage for which the item is designed.APGW
Current Rating At Maximum Rated Voltage:
10.0 amperes
MRC:
Indicates the type of current for which the coil is designed.APGZ
Coil Current Type:
Ac
MRC:
The amount of operating voltage,expressed in volts.APHA
Operating Voltage In Volts:
115.000
MRC:
The amount of operating current,expressed in amperes.APHB
Operating Current In Amps:
0.4
MRC:
The maximum opposition to the flow of direct current,expressed in ohms.APJX
Maximum Dc Resistance In Ohms:
8.4
MRC:
The designation that identifies the schematic diagram of the electrical configuration of a switch.APLQ
Switch Contact Arrangement:
3spst
MRC:
The maximum voltage rating at which the contact is rated,expressed in volts.APLS
Contact Maximum Voltage Rating In Volts:
115.000
MRC:
The amount of current at maximum rated voltage for which the contact/s/ is designed.APLT
Contact Current Rating At Maximum Rated Voltage:
10.0 amperes resistive
MRC:
An indication of the amount of voltage for which the contact/s/ is designed to withstand at the maximum rated current.APLX
Contact Voltage Rating At Maximum Rated Current:
115.0
MRC:
Consists of plating,dip,and/or coating that cannot be wiped off of the inclosure surface.APMK
Err Default:
Err default
MRC:
Consists of plating,dip,and/or coating that cannot be wiped off of the inclosure surface.APMK
Inclosure Surface Treatment:
Enamel
MRC:
The designation that identifies the schematic diagram of the contact configuration.CPWK
Contact Arrangement:
Dpdt