TXT
묘사:
Aircraft Fuel Syste Training Aid
MRC:
The direct current voltage for which the item is rated,expressed in volts.ACUR
Direct Current Voltage Rating In Volts:
28.000
MRC:
The cycles per second /hertz/ of the alternating current.AJSS
Frequency In Hertz:
400.000
MRC:
The installation for which the item is designed.AMQY
Installation Design:
Mobile
MRC:
The name of the government agency or commercial organization controlling the item.AMSA
Controlling Agency:
Mcdonnell-douglas corporation mcdonnell co
MRC:
The alternating current values of root mean square potential which must be applied to the item for operation,expressed in volts.ANWD
Ac Operating Voltage Rating In Volts:
26.000
MRC:
The address of the manufacturer.AQXF
Manufacturer Address:
St louis mo
MRC:
The source of power which provides the energy required for the operation of the item.AWZJ
Power Source:
Dc
MRC:
The source of power which provides the energy required for the operation of the item.AWZJ
Power Source:
Ac
MRC:
An identifying number assigned by the government agency or commercial organization controlling the item.AXEB
Identifying Number:
Tfe 303
MRC:
An indication of the alternating current usage by the item.AZZD
Alternating Current Usage:
Required
MRC:
An indication of the direct current usage by the item.AZZE
Direct Current Usage:
Required
MRC:
The name of the equipment.BBDX
Equipment Name:
Fuel system
MRC:
An indication of the special equipment the item simulates.CFTM
Special Equipment Simulated:
System
MRC:
The means used to present the functioning of the component(s) and/or item(s).CFTP
Component/item Functioning Presentation Method:
With operating gear
MRC:
The number of alternating current phases.FAAZ
Phase:
Single