MRC:
The size of the smallest particle which the element is capable of removing from the fluid which passes through the filtering material.ADNH
Filtration Rating In Microns:
25.0 absolute and 10.0
MRC:
The amount of pressure loss in the system,due to the resistance of flow through the item.ADNP
Drop Pressure:
4.9 pounds per square inch
MRC:
Indicates the design type of the item.APGF
Design Type:
Nonreusable
MRC:
A value which expresses the degree of heat or cold as applied to the operation,or limitation of operation,of an item.AZKQ
Tempurature Rating:
250.0 degrees fahrenheit
MRC:
The number of filtering elements provided.CCZM
Filtering Element Quantity:
2
MRC:
The maximum pressure at which the item is rated for operation.CQGM
Maximum Operating Pressure:
200.0 pounds per square inch
MRC:
Indicates the type of connection on the first intake.CRXZ
First Intake Connection Type:
Threaded internal pipe top
MRC:
Indicates the first discharge connection relationship to an intake connection.CSJR
First Discharge Connection Relationship To Intake Connection:
Identical to first intake connection
MRC:
A designation distinguishing one group of thread diameter-pitch combination from another by the number of threads per measurement scale for a specific diameter.CTDY
First Intake Thread Series Designator:
Nptf
MRC:
A designation that is used for the purpose of general identification of the thread.CTGK
First Intake Thread Size:
1.500 inches
MRC:
The direction of the thread when viewed axially.a right-hand thread winds in a clockwise direction while a left-hand thread winds in a counterclockwise direction.CXPF
First Intake Thread Direction:
Right-hand