TXT
묘사:
Electrical Receptacle Connector
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
1.027 inches
MRC:
A measurement of the longest straight line across a circular cross-sectional plane.ADAV
Overall Diameter:
1.438 inches
Distance From Mounting Shoulder To Front Face:
Between 0.478 inches and 0.488 inches
MRC:
The number of mating ends provided with the item which are designed to accommodate another connector.AFQW
Mating End Quantity:
1
MRC:
An indication of whether or not the contact(s) is removable.AFQZ
Contact Removability:
Nonremovable single mating end all contact groupings
MRC:
The means used to prevent mismating or cross plugging of contacts.AFRN
Polarization Method:
Keyway or multiple keyway
MRC:
The amount of clockwise displacement of the indexing radius of the insert from normal position,expressed in degrees.AFRP
Insert Position In Deg:
45.0
MRC:
Indicates the type of shell included on the item.AFRT
Shell Type:
Solid
MRC:
The means used to secure a connector to its mating counterpart.AFRV
Connector Locking Method:
Bayonet pin
MRC:
Indicates the location of the terminal/s/ on the item.CQTM
Terminal Location:
Back single mating end all contact groupings
MRC:
The chemical compound or mechanical mixture properties of which the insert is fabricated.CQZG
Insert Material:
Glass single mating end
MRC:
Indicates the type of terminal for providing electrical connection to the item.CSCF
Terminal Type:
Tab, solder lug single mating end all contact groupings
MRC:
The number of contacts included with the item which provides electrical connection.CXCG
Included Contact Quantity:
12 single mating end 1st contact grouping
MRC:
The number of contacts included with the item which provides electrical connection.CXCG
Included Contact Quantity:
4 single mating end 2nd contact grouping
MRC:
Indicates the type of contact(s) included with the item.CXCL
Included Contact Type:
Round pin single mating end all contact groupings