MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
3.260 inches
MRC:
The length of a straight line which passes through the center of a circular figure or body,and terminates at the outside circumference.ABKV
Outside Diameter:
0.500 inches all connections
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
3.290 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
1.750 inches
MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
1.920 inches
MRC:
The general classification of a pressure switch based on the reference method used to measure the sensed pressure.AJZC
Pressure Switch Type:
Gage
MRC:
The temperature at which the item operates.AWTN
Operating Tempurature Rating:
Between -60.0 degrees celsius and 65.0 degrees celsius
MRC:
The means of attaching the item.AXGY
Mounting Method:
Clamp
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Electrical box connector
MRC:
An indication of whether the initial action of the contacts occurs as the result of an increase or decrease in stimulus.CQGB
Contact Action Stimulus:
Increase
MRC:
The maximum pressure that an item will withstand without resulting in any permanent changes in the structural,mechanical,or electrical characteristics.CQJB
Proof Pressure:
150.00 pounds per square inch gage
MRC:
The designation that identifies the electrical configuration of a nonpile-up contact group including the number of switching poles or forms.CRLD
Nonpile-up Contact Arrangement:
1 pole, double throw, one position momentary
MRC:
The pressure at which the pressure sensing element of the item is rendered inoperative by rupture or other permanent physical damage.CSCC
Sensing Element Burst Pressure:
300.00 pounds per square inch gage
MRC:
Indicates the type of terminal for providing electrical connection to the item.CSCF
Terminal Type:
Connector, receptacle
MRC:
The amount of current that the contacts are rated to make or break with a specified load.CTHF
Contact Load Current Rating:
3.0 amperes inductive load second voltage
MRC:
The amount of current that the contacts are rated to make or break with a specified load.CTHF
Contact Load Current Rating:
0.5 amperes inductive load first voltage
MRC:
The adjustability of the contact.CTYC
Contact Adjustability:
Deactuation point not adjustable and actuation point not adjustable
MRC:
The rating of the stimulus required to actuate and/or deactuate the contact(s).CTYX
Contact Stimulus Rating:
0.80 actuation point gallons per minute and 0.19 differential point gallons per minute
MRC:
The voltage for which the contact(s) is rated at sea level or at a specified altitude,expressed in volts.CTZB
Contact Voltage Rating In Volts:
28.0 dc at sea level second voltage
MRC:
The voltage for which the contact(s) is rated at sea level or at a specified altitude,expressed in volts.CTZB
Contact Voltage Rating In Volts:
50.0 dc at sea level first voltage
MRC:
Indicates the type of pressure connector.CTZL
Pressure Connector Type:
Tapered, butt weld all connections
MRC:
The type of media for which the item is designed.MEDA
Media For Which Designed:
Gas
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Rectangular