TXT
묘사:
Pressure And Temper Relief Valve
MRC:
The basic material of which the body is fabricated.AAFZ
Body Material:
Brass
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
Body Style:
Angle give "adqm" and "adqn" only if flanged one or two ends
MRC:
A value which expresses the degree of heat or cold as applied to the operation,or limitation of operation,of an item.ABJH
Tempurature Rating:
-40.0 degrees fahrenheit
MRC:
A value which expresses the degree of heat or cold as applied to the operation,or limitation of operation,of an item.ABJH
Tempurature Rating:
225.0 degrees fahrenheit
MRC:
The type of service with which the item is designed to be used.ACKL
Media For Which Designed:
Refrigerant
MRC:
A narrative description of the type of end connection.ACKM
First End Connection Type:
Threaded external tube
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the end.ACKN
First End Style Designator:
Flared
MRC:
The length of a straight line which passes through the center of the accommodated tube,and terminates at the outside circumference.ACLH
First End Outside Diameter Tube Accommodated:
0.625 inches
MRC:
Designates the thread diameter,series/type,and number of threads per specific measurement scale.ACLJ
First End Thread Size And Series/type Designator:
0.875 unjf
MRC:
A numeric-alpha designator indicating the pitch diameter tolerance and an external or internal thread.ACLK
First End Thread Class:
3a
MRC:
The direction of the thread when viewed axially. a right-hand thread winds in a clockwise direction while a left-hand thread winds in a counterclockwise direction.ACLL
First End Thread Direction:
Right-hand
MRC:
Indicates whether or not the second end is identical to the first end.ACLR
Second End Relationship With First End:
Not identical
MRC:
A narrative description of the type of end connection.ACLS
Second End Connection Type:
Threaded external pipe
MRC:
The industrial designation or term used to define the nominal diameter of the pipe the end will accommodate.ACMN
Second End Pipe Size Accommodated:
0.500 inches
MRC:
Designates the thread diameter,series/type,and number of threads per specific measurement scale.ACMQ
Second End Thread Size And Series/type Designator:
0.750-16 unjf
MRC:
The direction of the thread when viewed axially. a right-hand thread winds in a clockwise direction while a left-hand thread winds in a counterclockwise direction.ACMS
Second End Thread Direction:
Right-hand
MRC:
The number of end connections included in the item.ADQZ
End Connection Quantity:
2
MRC:
The rated valve discharge capacity per unit of time.ADSY
Valve Discharge Flow Rate:
259.35 cubic feet per minute
MRC:
A measurement of the longest dimension of a bulb.AEVU
Bulb Length:
3.562 inches
MRC:
An indication of whether or not the temperature is adjustable.AEVX
Tempurature Adjustability:
Not adjustable