TXT
묘사:
Photogr Temperature Control Unit
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Ac
MRC:
The type of service with which the item is designed to be used.ACKL
Media For Which Designed:
Cooling or heating or unprocessed film
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
Between 50.0 hertz and 60.0 hertz
MRC:
An indication of whether or not a container from which the item is completely removable in normal operable condition is provided.AFJU
Carrying Case:
Not provided
MRC:
An indication of whether or not a support stand is included with the item.AGBA
Support Stand:
Not included
MRC:
An indication of whether or not a self-priming feature is included.AHZH
Err Default:
Err default
MRC:
An indication of whether or not a self-priming feature is included.AHZH
Self-priming Feature:
Included
MRC:
The element,compound,or mixture of which the cabinet is fabricated,excluding any surface treatment.AZSB
Cabinet Material:
Steel
MRC:
The minimum rate at which the item can circulate water.BJBB
Err Default:
Err default
MRC:
The minimum rate at which the item can circulate water.BJBB
Minimum Water Circulation Rate:
900.0 gallons per hour
MRC:
An indication of whether or not an additional cabinet mounted processing tank is included.BJLH
Err Default:
Err default
MRC:
An indication of whether or not an additional cabinet mounted processing tank is included.BJLH
Extra Processing Tank Cabinet Mounted:
Not included
MRC:
Consists of plating,dip,and/or coating that cannot be wiped off. plating and/or coating is any chemical and/or metallic additive,electrochemical,or mild mechanical process which protects the surface of the cabinet.BJMB
Err Default:
Err default
MRC:
Consists of plating,dip,and/or coating that cannot be wiped off. plating and/or coating is any chemical and/or metallic additive,electrochemical,or mild mechanical process which protects the surface of the cabinet.BJMB
Cabinet Surface Treatment:
Enamel
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the cabinet.BJMC
Err Default:
Err default
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the cabinet.BJMC
Cabinetlength:
24.000 inches
MRC:
An overall measurement taken at right angles to the length of a cabinet,in distinction from thickness.BJNW
Err Default:
Err default
MRC:
An overall measurement taken at right angles to the length of a cabinet,in distinction from thickness.BJNW
Cabinetwidth:
15.000 inches
MRC:
The distance measured in a straight line from the bottom to the top of the cabinet.BJNX
Err Default:
Err default
MRC:
The distance measured in a straight line from the bottom to the top of the cabinet.BJNX
Cabinetheight:
16.000 inches
MRC:
The total electrical voltage.ELEC
Voltage In Volts:
230.0
MRC:
The number of alternating current phases.FAAZ
Phase:
Single