MRC:
A measurement of the smallest dimension of a flange,in distinction from length or width.ABKU
Flange Thickness:
14.50 millimeters
MRC:
The length of a straight line which passes through the center of a flange,and terminates at the outside circumference.AHTC
Flange Outside Diameter:
95.00 millimeters
MRC:
The design of the body of the item.ALCS
Body Design:
Straight pattern
MRC:
The element,compound,or mixture of which the item is fabricated,excluding any surface treatment,and its location.ANNQ
Material And Location:
Nickel copper alloy strainer err-100 err-100
MRC:
The element,compound,or mixture of which the item is fabricated,excluding any surface treatment,and its location.ANNQ
Material And Location:
Steel body err-100 err-100
MRC:
Indicates the design type of the item.APGF
Design Type:
Pulsating
MRC:
The length of a straight line which passes through the center of the flange bolt hole,and terminates at the circumference.ARZJ
Flange Bolt Hole Diameter:
10.00 millimeters
MRC:
The number of bolt holes in the flange.AXAQ
Flange Bolt Hole Quantity:
4
MRC:
The maximum steam pressure at which the item is designed to operate.AXSW
Maximum Steam Working Pressure:
1500.0 pounds per square inch
MRC:
An indication of whether or not a strainer is included.BMBL
Strainer:
Included
MRC:
The rated capacity of the item at maximum working pressure.BZSX
Rated Capacity At Maximum Working Pressure:
Not rated
MRC:
An indication of whether or not the inlet and/or outlet connection(s) is identical.BZTB
Inlet/outlet Connection Similarity:
Identical
MRC:
The value used to define the nominal diameter of the inlet and/or outlet connection pipe.BZTC
Inlet/outlet Connection Pipe Size:
0.500 inches
MRC:
Indicates the type of inlet and/or outlet connection provided.BZTD
Inlet/outlet Connection Type:
Flanged
MRC:
Indicates the type of flange facing provided.BZTF
Flange Facing Type:
Raised
MRC:
The length of a straight line which passes through the center of a flange bolt circle,and terminates at the circumference.BZTG
Err Default:
Err default
MRC:
An indication of whether or not the inlet and/or outlet connection is threaded.BZTH
Inlet/outlet Connection Thread Provision:
Unthreaded
MRC:
Indicates the location of the inlet in relation to the installed position of the item.BZTJ
Inlet Location In Relation To Installed Position:
Lower side
MRC:
Indicates the location of the outlet in relation to the installed position of the item.BZTK
Outlet Location In Relation To Installed Position:
Lower side
MRC:
An indication of whether or not a gage glass is included.BZTL
Gage Glass:
Not included