TXT
묘사:
Pressure Transmitter
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Dc
MRC:
The means by which the item is actuated.AFLW
Actuation Method:
Diaphragm
MRC:
The number of contacts which provide electrical connection.AFRA
Contact Quantity:
1
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
Halverson loader
MRC:
Indicates the type of contact(s) included on the item.AKSF
Contact Type:
Terminal stud
MRC:
The value(s) of potential for which the item is rated.AMSE
Voltage Rating:
12.0 pounds per hour wet input
MRC:
The number of mechanical connections provided.ASSB
Mechanical Connection Quantity:
1
MRC:
Designates the thread size,diameter,or the like,of the mechanical connection.ASSC
Mechanical Connection Size:
0.125 in npt, includes adapter for 0.250 in npt
MRC:
Indicates the type of mechanical connection/s/ provided.ASSD
Mechanical Connection Type:
External pipe
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+0.0/+100.0 pounds pressure per square inch
MRC:
The master requirement codes of those requirements which are technically critical by reason of tolerance,fit,performance,or other characteristics which affect identification of the item.CRTL
Criticality Code Justification:
Spcl
MRC:
Literature and references available for information pertaining to the item.RDAL
Reference Data And Literature:
Fmc airport systems drawing and stewart warner commercial data
MRC:
Test conditions and ratings,or environmental and performance requirements that are different,more critical,or more specific than those specified in a governing test data document.SPCL
Special Test Features:
Item has been tested for radiated electromagnetic emissions iaw air force ground requirements mil-std-461d using methods re102 and rs103. Items has been tested for electromagnetic compatibility iaw air force ground requirements mil-std-462d using methods re102 and rs103