MRC:
The part that controls the flow through the item.ADQU
Flow Control Device:
Piston
MRC:
The maximum temperature at which the item is rated to operate for an extended period of time.AEHZ
Maximum Operating Temp:
275.0 degrees fahrenheit single response
MRC:
The means used to control the operation of the valve.AQLR
Valve Operation Method:
Manual
MRC:
The maximum pressure at which the item is rated for operation.CQGM
Maximum Operating Pressure:
3000.0 pounds per square inch single response
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Aluminum alloy body
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Steel comp 630 flow control device
MRC:
The specification,standard,or manufacturers reference,and the classification designation,such as class,condition,temper,and the like,that identifies the material.MDCL
Material Specification:
Ams 5643 assn standard single material response flow control device
MRC:
The specification,standard,or manufacturers reference,and the classification designation,such as class,condition,temper,and the like,that identifies the material.MDCL
Material Specification:
Qq-a-367 federal specification single material response body
MRC:
The type of media for which the item is designed.MEDA
Media For Which Designed:
Fuel/oil, hydrocarbon single response
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Err-090