MRC:
The distance measured in a straight line from the bottom to the top of an item.AAJT
Overall Height:
4.216 inches
MRC:
A measurement of the longest dimension of an item,in distinction from width.AAJU
Overall Length:
2.559 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.AAJV
Overall Width:
2.323 inches
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Ac input
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Ac output
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
6920-01-349-2713
MRC:
The direction of rotation of a rotating shaft as viewed from the drive end.AKCT
Shaft Rotation Direction:
Clockwise second end
MRC:
The direction of rotation of a rotating shaft as viewed from the drive end.AKCT
Shaft Rotation Direction:
Clockwise first end
MRC:
The working period under which the item was designed to operate.AKPS
Duty Cycle:
Continuous
MRC:
Indicates the type and number of facilities by which the item is mounted.AXHR
Mounting Facility Type And Quantity:
6 unthreaded hole
MRC:
The means of cooling used to maintain the required operating temperature of the item.BFMF
Cooling Method:
Ambient air
MRC:
Indicates the torque rating,and its type.BKPH
Torque Rating And Type:
1.90 inch-ounces running
MRC:
A measurement of the longest dimension of the shaft projection of an item,in distinction from width.CWCS
Length Of Shaft From Housing:
0.244 inches second end
MRC:
A measurement of the longest dimension of the shaft projection of an item,in distinction from width.CWCS
Length Of Shaft From Housing:
1.055 inches first end
MRC:
The nominal center to center distance between the mounting facilities parallel to the length.CWDT
Center To Center Distance Between Mounting Facilities Parallel To Length:
1.812 inches
MRC:
The temperature at which the item is designed to operate.CWDY
Tempurature Rating:
-15.0 ambient degrees celsius and 55.0 ambient degrees celsius
MRC:
The length of a straight line which passes through the center of a mounting facility circle,and terminates at the circumference.CWFQ
Mounting Facility Circle Diameter:
0.177 inches
MRC:
The nominal center to center distance between the mounting facilities parallel to the width.CWFY
Center To Center Distance Between Mounting Facilities Parallel To Width:
1.968 inches
MRC:
The speed rating of the geared head output shaft(s).CWHK
Geared Head Output Shaft Speed Rating:
1.000 single revolutions per hour second end
MRC:
The speed rating of the geared head output shaft(s).CWHK
Geared Head Output Shaft Speed Rating:
1.000 single revolutions per hour first end
MRC:
An indication of the characteristic(s) of the shaft end.CWHZ
Shaft End Characteristic:
A1 single style first end
MRC:
An indication of the characteristic(s) of the shaft end.CWHZ
Shaft End Characteristic:
A12 single style second end
MRC:
The number of alternating current phases.FAAZ
Phase:
Single input
MRC:
The number of alternating current phases.FAAZ
Phase:
Single output
MRC:
The cycles per second /hertz/ of the alternating current.FREQ
Frequency In Hertz:
60.0 input
MRC:
The cycles per second /hertz/ of the alternating current.FREQ
Frequency In Hertz:
60.0 output
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
4 wire lead