TXT
묘사:
Steam Turbine Generator Set
MRC:
Indicates the type of mount utilized to support the item.AAXX
Mounting Type:
Base
MRC:
The steam pressure required to motivate the steam engine or turbine used as the prime mover.AAYL
Steam Operating Pressure:
440.0 pounds per square inch gage
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
176.563 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
158.438 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
73.500 inches
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Ac
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
60.0 hertz
MRC:
The number of parts supplied with the item which may be required for application.AFHS
Accessory Component Quantity:
1
MRC:
The temperature of the steam required to operate an item at full capacity.AJAA
Steam Tempurature Rating:
740.0 degrees fahrenheit
MRC:
The name of the government agency or commercial organization that controls the manufacture of the accessory item.AKVY
Accessory Controlling Agency:
C. H. Wheeler mfg co
MRC:
The specific number used to identify the accessory.AKVZ
Accessory Identifying Number:
Dwg no. 58589
MRC:
Indicates the type of stage.AWNT
Stage Type:
Multiple
MRC:
The alternating current for which the item is rated,expressed in watts.AYGY
Ac Wattage Rating:
1500.0 kilowatts
MRC:
The total electrical line to line voltage for which the item is rated,expressed in volts.AYHB
Line To Line Voltage In Volts:
450.0
MRC:
The ratio between actual rated power,and power required by a specified load applied to the item,expressed in percent.AYHD
Power Factor In Percent:
0.8
MRC:
Indicates the type of excitor provided.AYHE
Excitor Type:
Self-excited
MRC:
An indication of whether or not an excitor is included.AYHF
Excitor:
Not included
MRC:
The name of the manufacturer of the prime mover.AZBN
Prime Mover Manufacturer Name:
General electric co
MRC:
Indicates the design type characteristic/s/ of the turbine.AZBQ
Turbine Design Type:
Impulse
MRC:
Indicates the type of exhaust provided.AZBR
Exhaust Type:
Condensing
MRC:
The means provided for coupling the turbine to the generator.AZBS
Turbine To Generator Coupling Method:
Gear train
MRC:
The name of the accessory component assigned by the controlling agency.AZCG
Accessory Component Name:
Condenser
MRC:
The ambient temperature of the medium surrounding an item at which it can be operated,expressed in degrees celsius.AZCL
Ambient Tempurature In Deg Celsius:
50.0
MRC:
The permissible temperature increase for continuous operation,at which the item is rated,expressed in degrees celsius.AZCM
Tempurature Rise Rating In Deg Celsius For Continuous Operation:
Not rated
MRC:
The number of alternating current phases.FAAZ
Phase:
Three