TXT
묘사:
Hydraulic System Comp Test Stand
MRC:
The amount of hydraulic fluid required to operate the item.AAYJ
Hydraulic Fluid Flow Rate:
40.0 gallons per minute
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Ac
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
Titan engine age.
MRC:
Indicates the type of drive for turning,rotating,or positioning the mechanism.AKCV
Drive Type:
Shaft
MRC:
Indicates the designed use of the item.ALBY
Usage Design:
Individual hydraulic units
MRC:
The installation for which the item is designed.AMQY
Installation Design:
Fixed
MRC:
An indication of the rated horsepower of the item.ANCY
Horsepower Rating:
7.5
MRC:
The source of power which drives the item.ATJK
Power Source:
Electric motor
MRC:
The maximum speed at which the item is designed to operate,expressed in revolutions per minute.ATPR
Maximum Speed Rating In Rpm:
5000.0
MRC:
An indication of whether or not an accumulator is included.AYJM
Accumulator:
Not included
MRC:
The pressure at which an item is designed to operate.BGST
Pressure Rating:
350.0 pounds per square inch
MRC:
The maximum pressure at which the item is designed to operate.BJDW
Maximum Operating Pressure:
350.0 pounds per square inch
MRC:
An indication of whether or not a design feature for testing engine driven hydraulic pumps is included.CGYK
Engine Driven Hydraulic Pump Testing Design Feature:
Included
MRC:
The rated flow capacity of the item.CGYL
Flow Capacity Rating:
40.0 gallons per minute
MRC:
An indication of whether or not a pressure manifold subcircuit(s) is included.CGYM
Pressure Manifold Subcircuit:
Included
MRC:
The number of subcircuits provided and the maximum operating pressure of each subcircuit.CHGN
Subcircuit Quantity And Maximum Operating Pressure:
Two 350 and 40 psi
MRC:
An indication of whether or not a filtering system is included.CHGQ
Filtering System:
Included
MRC:
An indication of whether or not a pressure and suction hose are included.CHGR
Pressure/suction Hose:
Not included
MRC:
The total electrical voltage.ELEC
Voltage In Volts:
220.0
MRC:
The number of alternating current phases.FAAZ
Phase:
Three
MRC:
The alpha-numeric designation that identifies the classification of the item according to the category of functions performed.FCLS
Functional Classification:
Gg-7.3
MRC:
The cycles per second /hertz/ of the alternating current.FREQ
Frequency In Hertz:
60.0
MRC:
Literature and references available for information pertaining to the item.RDAL
Reference Data And Literature:
T.O. 33d4-7-4-4