TXT
묘사:
Transformer Assembly
MRC:
An indication that the level of probability that an item will operate without failure,at a specified rated capability,at a specified temperature,and for a specified period of time,has been established by testing random samples of production lot.AARG
Reliability Indicator:
Not established
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
Between 2.390 inches and 2.430 inches
MRC:
The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the length.ABKQ
Center To Center Distance Between Mounting Facilities Parallel To Length:
1.730 inches single mounting facility single center group and 1.770 inches single mounting facility single center group
MRC:
The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the width.ABKR
Center To Center Distance Between Mounting Facilities Parallel To Width:
1.410 inches single mounting facility single center group and 1.450 inches single mounting facility single center group
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
Between 5.068 inches and 5.088 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
Between 2.117 inches and 2.217 inches
MRC:
A measurement taken at right angles to the length of the mounting slot,in distinction from thickness.ABTD
Mounting Slot Width:
0.115 inches single group and 0.135 inches single group
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
400.0 hertz all components
MRC:
The relationship of the phase input to the phase output of an alternating current.ACZC
Input-output Phase Relationship:
Single phase to single phase all components
MRC:
The maximum amount of power for which the transformer is rated.ACZF
Maximum Transformer Power Rating:
195.5 volt-ampere all components
MRC:
The means by which a protective metal screen,plate,or inclosure is placed around or between the windings of an item to prevent electrostatic or magnetic coupling.ACZX
Winding Shielding Method:
Internal shield brought out to terminal all components
MRC:
The maximum temperature at which the item is rated to operate for an extended period of time.AEHZ
Maximum Operating Temp:
104.0 degrees celsius
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Fully enclosed
MRC:
The number of mounting facilities provided.AKPV
Mounting Facility Quantity:
4 single group
MRC:
The means of attaching the item.AXGY
Mounting Method:
Slot single group
MRC:
The means by which the rating is determined.BKPL
Rating Method:
Electrical all components all secondary
MRC:
The means by which the rating is determined.BKPL
Rating Method:
Electrical all components single primary
MRC:
The purpose and the total number of individual (not electrically connected) windings designed to perform in a transformer.BPLC
Winding Function And Quantity:
1 primary 1st component and 2 secondary 1st component
MRC:
The purpose and the total number of individual (not electrically connected) windings designed to perform in a transformer.BPLC
Winding Function And Quantity:
1 primary 2nd component and 4 secondary 2nd component
MRC:
The amount of operating current for which the winding is designed.CRBZ
Winding Operating Current:
15.0 milliamperes ac 2nd component 2nd secondary
MRC:
The amount of operating current for which the winding is designed.CRBZ
Winding Operating Current:
1.7 amperes ac all components single primary
MRC:
The amount of operating current for which the winding is designed.CRBZ
Winding Operating Current:
100.0 milliamperes ac 2nd component 3rd secondary
MRC:
The amount of operating current for which the winding is designed.CRBZ
Winding Operating Current:
100.0 milliamperes ac 2nd component 4th secondary
MRC:
The amount of operating current for which the winding is designed.CRBZ
Winding Operating Current:
800.0 milliamperes ac 1st component 1st secondary
MRC:
The amount of operating current for which the winding is designed.CRBZ
Winding Operating Current:
640.0 milliamperes ac 2nd component 1st secondary
MRC:
The amount of operating current for which the winding is designed.CRBZ
Winding Operating Current:
75.0 milliamperes ac 1st component 2nd secondary and 400.0 milliamperes ac 1st component 2nd secondary
MRC:
The opposition to the flow of direct current offered by an item,expressed in ohms.CRGS
Dc Resistance Rating In Ohms:
0.0886 1st component 1st secondary
MRC:
The opposition to the flow of direct current offered by an item,expressed in ohms.CRGS
Dc Resistance Rating In Ohms:
0.540 2nd component 4th secondary
MRC:
The opposition to the flow of direct current offered by an item,expressed in ohms.CRGS
Dc Resistance Rating In Ohms:
0.700 all components single primary
MRC:
The opposition to the flow of direct current offered by an item,expressed in ohms.CRGS
Dc Resistance Rating In Ohms:
0.7932 2nd component 1st secondary
MRC:
The opposition to the flow of direct current offered by an item,expressed in ohms.CRGS
Dc Resistance Rating In Ohms:
4.300 2nd component 3rd secondary
MRC:
The opposition to the flow of direct current offered by an item,expressed in ohms.CRGS
Dc Resistance Rating In Ohms:
52.200 2nd component 2nd secondary
MRC:
The opposition to the flow of direct current offered by an item,expressed in ohms.CRGS
Dc Resistance Rating In Ohms:
7.800 1st component 2nd secondary
MRC:
The maximum power for which the winding of the item is rated.CRMJ
Winding Power Rating:
19.44 volts-amperes 1st component 1st secondary
MRC:
The maximum power for which the winding of the item is rated.CRMJ
Winding Power Rating:
195.5 volts-amperes all components single primary
MRC:
The maximum power for which the winding of the item is rated.CRMJ
Winding Power Rating:
2.4 volts-amperes 2nd component 2nd secondary
MRC:
The maximum power for which the winding of the item is rated.CRMJ
Winding Power Rating:
2.62 volts-amperes 2nd component 4th secondary
MRC:
The maximum power for which the winding of the item is rated.CRMJ
Winding Power Rating:
2.56 volts-amperes 2nd component 3rd secondary
MRC:
The maximum power for which the winding of the item is rated.CRMJ
Winding Power Rating:
44.96 volts-amperes 1st component 2nd secondary
MRC:
The maximum power for which the winding of the item is rated.CRMJ
Winding Power Rating:
45.824 volts-amperes 2nd component 1st secondary
MRC:
The value/s/ of the operating voltage applied to the winding.CWJS
Winding Operating Voltage:
14.70 ac volts 2nd component 1st secondary and 56.90 ac volts 2nd component 1st secondary and 71.60 ac volts 2nd component 1st secondary
MRC:
The value/s/ of the operating voltage applied to the winding.CWJS
Winding Operating Voltage:
159.70 ac volts 2nd component 2nd secondary
MRC:
The value/s/ of the operating voltage applied to the winding.CWJS
Winding Operating Voltage:
115.00 ac volts all components single primary
MRC:
The value/s/ of the operating voltage applied to the winding.CWJS
Winding Operating Voltage:
26.20 ac volts 2nd component 4th secondary
MRC:
The value/s/ of the operating voltage applied to the winding.CWJS
Winding Operating Voltage:
24.30 ac volts 1st component 1st secondary
MRC:
The value/s/ of the operating voltage applied to the winding.CWJS
Winding Operating Voltage:
25.60 ac volts 2nd component 3rd secondary
MRC:
The value/s/ of the operating voltage applied to the winding.CWJS
Winding Operating Voltage:
33.85 ac volts 1st component 2nd secondary and 38.30 ac volts 1st component 2nd secondary and 41.50 ac volts 1st component 2nd secondary and 70.90 ac volts 1st component 2nd secondary and 74.10 ac volts 1st component 2nd secondary and 78.55 ac volts 1st component 2nd secondary and 112.40 ac volts 1st component 2nd secondary
MRC:
The specification,standard,drawing,or similar instrument that specifies environmental and performance requirements or test conditions under which an item is tested and establishes acceptable limits within which the item must conform identified by an alphabetic and/or numeric reference number. includes the commercial and government entity (cage) code of the entity controlling the instrument.TEST
Test Data Document:
16340-11-00151 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
30 turret