부품 정보
Gauge, water/foam lvl, ic, 5-lt
TXT
묘사:
Liquid Quantity Indicator
MRC:
The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the length.ABKQ
Center To Center Distance Between Mounting Facilities Parallel To Length:
4.880 inches
MRC:
The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the width.ABKR
Center To Center Distance Between Mounting Facilities Parallel To Width:
1.500 inches
MRC:
The length of a straight line which passes through the center of a mounting hole,and terminates at the circumference.ABTB
Mounting Hole Diameter:
0.210 inches
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
2320-01-528-6294 truck, tank, hemtt based water tender (hewatt)
MRC:
Indicates the type of presentation.AMNL
Presentation Type:
Indicator light
MRC:
The style designation indicating the configuration that most nearly corresponds to the arrangement of the mounting.ANRL
Mounting Arrangement Style:
Four slot rectangular/square
MRC:
Those unusual or unique characteristics or qualities of an item not covered in the other requirements and which are determined to be essential for identification.FEAT
Special Features:
Pin probe and pin slave: red: power, black: ground, brown: empty refill signal, green: 1/4level, white: 1/2level, blue: 3/4level, orange: full level