TXT
묘사:
Fluid Cooler Core Assembly
MRC:
The length of a straight line which passes through the center of the core,and terminates at the circumference.AKMH
Core Diameter:
10.250 inches
MRC:
A measurement of the longest dimension of the core,in distinction from width.AKMJ
Core Length:
4.500 inches
MRC:
The length of a straight line which passes through the center of the tubing,and terminates at the outside circumference.AQRX
Tubing Outside Diameter:
0.250 inches outer tube outlet end
MRC:
The number of tubes included on the item.ARNF
Tube Quantity:
394
MRC:
The means by which the tube/s/ is attached.AWMZ
Tube Attachment Method:
Expanded both ends
MRC:
A measurement of the surface of the item that effects the transfer of heat.CTRC
Effective Heat Transfer Surface Area:
116.0 square feet
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Copper alloy tubes
MRC:
The specification,standard,or manufacturers reference,and the classification designation,such as class,condition,temper,and the like,that identifies the material.MDCL
Material Specification:
Mil-c-15726, comp 70-30 military specification single material response tubes
MRC:
The number,letter,or symbol that indicates the type,style,grade,class,and the like,of an item in a nonidentifying specification or standard.ZZZT
Specification Or Standard:
A type and 1 class