MRC:
A recording of the physical,functional,and performance characteristics for an item of supply.TEXT
General Description:
1.160 in. W, 1.450 in. H, 4 holes 0.154 plus or min in. Dia, indicator shall not actuate below 20 degrees f fluid temperature and shall actuate above 50 degrees f, the electrical indicator switch shall actuate to position 2 when the red button extends, or shall give a visual warning and actuate the electrical switch to pos 2 when the diff press is 70 plus or mis 10 psi, unit is required to successfully pass acceptance test per tp4808824, unit shall withstand a proof pressure of 2250 psi without malfunction, unit shall conform to bll helicopter co specification no.212-076-006