TXT
묘사:
S Electrical Insulation Sleeving
MRC:
The maximum voltage the insulating materials of the item will withstand without resulting in disruptive discharge or deterioration,expressed in volts.AAPB
Dielectric Withstanding Voltage In Volts:
10000.0
MRC:
A value which expresses the degree of heat or cold as applied to the operation,or limitation of operation,of an item.ABJH
Tempurature Rating:
-55.0 degrees celsius and 80.0 degrees celsius
MRC:
The environmental elements or conditions that an item is designed or protected to resist or withstand satisfactorily.ADZC
Environmental Protection:
Any acceptable
Main Body Inside Diameter:
1.000 inches after unrestricted recovery
Main Body Inside Diameter:
2.190 inches as supplied
First Branch Inside Diameter:
0.490 inches after unrestricted recovery
First Branch Inside Diameter:
1.050 inches as supplied
Second Branch Inside Diameter:
0.490 inches after unrestricted recovery
Second Branch Inside Diameter:
1.060 inches as supplied
Third Branch Inside Diameter:
0.490 inches after unrestricted recovery
Third Branch Inside Diameter:
1.060 inches as supplied
Distance From Intersecting Centerline Of Main Body To End Of First Branch:
4.060 inches as supplied
Distance From Intersecting Centerline Of Main Body To End Of First Branch:
4.470 inches after unrestricted recovery
Distance From Intersecting Centerline Of Main Body To End Of First Branch:
3.650 inches after unrestricted recovery
Main Body Wall Thickness:
0.180 inches as supplied
Main Body Wall Thickness:
0.140 inches after unrestricted recovery
Main Body Wall Thickness:
0.220 inches after unrestricted recovery
First Branch Wall Thickness:
0.080 inches after unrestricted recovery
First Branch Wall Thickness:
0.120 inches after unrestricted recovery
First Branch Wall Thickness:
0.100 inches as supplied
Second Branch Wall Thickness:
0.080 inches after unrestricted recovery
Second Branch Wall Thickness:
0.100 inches as supplied
Second Branch Wall Thickness:
0.120 inches after unrestricted recovery
Third Branch Wall Thickness:
0.120 inches after unrestricted recovery
Third Branch Wall Thickness:
0.080 inches after unrestricted recovery
Third Branch Wall Thickness:
0.100 inches as supplied
Distance From Edge Of Main Body To Intersecting Centerlines:
3.500 inches as supplied
Distance From Edge Of Main Body To Intersecting Centerlines:
3.150 inches after unrestricted recovery
Distance From Edge Of Main Body To Intersecting Centerlines:
3.850 inches after unrestricted recovery
Main Bodylength:
6.800 inches after unrestricted recovery
Main Bodylength:
8.320 inches after unrestricted recovery
Main Bodylength:
8.330 inches as supplied
Angle Between Main Body And First Branch Centerlines In Deg:
20.0 as supplied
Angle Between Main Body And First Branch Centerlines In Deg:
25.0 after unrestricted recovery
Angle Between Main Body And First Branch Centerlines In Deg:
35.0 after unrestricted recovery
MRC:
The maximum rated load in tension applied in a longitudinal direction,per unit of cross-sectional area,that the material can withstand without rupture.CQBC
Min. Tensile Strength (psi):
1500 pounds per square inch
MRC:
Flexible,capable of being bent,turned or twisted,within limits,without breaking,or rigid,resisting change of form,inflexible.FLEX
Flexibility:
Flexible
MRC:
A characteristic of light that can be specified in terms of luminance,dominant wavelength,and purity.HUES
Color:
Black
MRC:
The element,compound,or mixture of which an item is fabricated,excluding any surface treatment.MATL
Material:
Rubber, chloroprene
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Rubber chloroprene class cr
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Transition-1 to 3 cables