MRC:
						The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
					 
					
						Body Style:
					
					
						Flush mounted					
				 
							
					
						MRC:
						The specific commercial rating which classes the item as to what degree the item will withstand environmental elements and/or hazardous locations.ABFE
					 
					
						Hazardous Locations/environmental Protection:
					
					
						Shock resistant and vibration resistant					
				 
							
					
						MRC:
						A measurement of the longest dimension of the body,in distinction from width.ADAQ
					 
					
						Body Length:
					
					
						1.590 inches 					
				 
							
					
						MRC:
						A measurement taken at right angles to the length of the body,in distinction from thickness.ADAT
					 
					
						Body Width:
					
					
						1.000 inches 					
				 
							
					
						MRC:
						A measurement from the bottom to the top of the body,in distinction from depth.ADAU
					 
					
						Body Height:
					
					
						1.000 inches 					
				 
							
					
						MRC:
						The measurement of the distance that the actuator protrudes from the body.AFGK
					 
					
						Actuator Length:
					
					
						0.250 inches 					
				 
							
					
						MRC:
						The style designation indicating the configuration that most nearly corresponds to the appearance of the actuator.AFUQ
					 
					
						Actuator Style:
					
					
						Round					
				 
							
					
						MRC:
						A measurement taken at right angles to the length of the actuator,in distinction from thickness.AFUT
					 
					
						Actuator Width:
					
					
						Between 0.058 inches and 0.068 inches 					
				 
							
					
						MRC:
						The maximum voltage rating at which the item is designed to operate in an alternating current and/or direct current circuit,expressed in volts.AFXE
					 
					
						Maximum Voltage Rating In Volts:
					
					
						35.0 dc					
				 
							
					
						MRC:
						Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
					 
					
						Inclosure Type:
					
					
						Fully enclosed					
				 
							
					
						MRC:
						The means of attaching the item.AXGY
					 
					
						Mounting Method:
					
					
						Printed circuit					
				 
							
					
						MRC:
						The amount of current the contacts are rated to make or break at maximum rated voltage,with a specified load.CXQR
					 
					
						Contact Load Current Rating At Maximum Rated Voltage:
					
					
						0.050 amperes resistive dc					
				 
							
					
						MRC:
						Indicates the type and number of terminals for providing electrical connection.TTQY
					 
					
						Terminal Type And Quantity:
					
					
						1 socket,  integrated wire termination