TXT
묘사:
Electrical Plug Connector
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
Body Style:
Straight shape w/clamp
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
3.109 inches
MRC:
A measurement of the longest straight line across a circular cross-sectional plane.ADAV
Overall Diameter:
1.937 inches
MRC:
The length of a straight line which passes through the center of the cable entrance,and terminates at the circumference.AFQJ
Cable Entrance Diameter:
Between 0.385 inches and 0.843 inches
MRC:
The number of mating ends provided with the item which are designed to accommodate another connector.AFQW
Mating End Quantity:
1
MRC:
The style designation indicating the configuration that most nearly corresponds to the arrangement of the contact position/s/.AFQX
Contact Position Arrangement Style:
3 single mating end
MRC:
An indication of whether or not the contact(s) is removable.AFQZ
Contact Removability:
Nonremovable single mating end 1st contact grouping
MRC:
An indication of whether or not the contact(s) is removable.AFQZ
Contact Removability:
Nonremovable single mating end 2nd contact grouping
MRC:
An indication of whether or not the contact(s) is removable.AFQZ
Contact Removability:
Nonremovable single mating end 3rd contact grouping
MRC:
The maximum current which the contact may continuously carry without degradation or destruction,expressed in amperes.AFRC
Contact Maximum Current Rating In Amps:
20.0 single mating end 1st contact grouping
MRC:
The maximum current which the contact may continuously carry without degradation or destruction,expressed in amperes.AFRC
Contact Maximum Current Rating In Amps:
20.0 single mating end 2nd contact grouping
MRC:
The maximum current which the contact may continuously carry without degradation or destruction,expressed in amperes.AFRC
Contact Maximum Current Rating In Amps:
20.0 single mating end 3rd contact grouping
MRC:
The maximum alternating current potential that may be applied continuously to the contact without damage,expressed in volts.AFRD
Contact Maximum Ac Voltage Rating In Volts:
125.0 single mating end 1st contact grouping
MRC:
The maximum alternating current potential that may be applied continuously to the contact without damage,expressed in volts.AFRD
Contact Maximum Ac Voltage Rating In Volts:
125.0 single mating end 2nd contact grouping
MRC:
The maximum alternating current potential that may be applied continuously to the contact without damage,expressed in volts.AFRD
Contact Maximum Ac Voltage Rating In Volts:
125.0 single mating end 3rd contact grouping
MRC:
The maximum direct current potential that may be applied continuously to the contact without damage,expressed in volts.AFRE
Contact Maximum Dc Voltage Rating In Volts:
125.0 single mating end 1st contact grouping
MRC:
The maximum direct current potential that may be applied continuously to the contact without damage,expressed in volts.AFRE
Contact Maximum Dc Voltage Rating In Volts:
125.0 single mating end 2nd contact grouping
MRC:
The maximum direct current potential that may be applied continuously to the contact without damage,expressed in volts.AFRE
Contact Maximum Dc Voltage Rating In Volts:
125.0 single mating end 3rd contact grouping
MRC:
The maximum frequency at which the contact is rated.AFRF
Contact Maximum Frequency Rating:
60.0 kilohertz single mating end 1st contact grouping
MRC:
The maximum frequency at which the contact is rated.AFRF
Contact Maximum Frequency Rating:
60.0 kilohertz single mating end 2nd contact grouping
MRC:
The maximum frequency at which the contact is rated.AFRF
Contact Maximum Frequency Rating:
60.0 kilohertz single mating end 3rd contact grouping
MRC:
The means used to prevent mismating or cross plugging of contacts.AFRN
Polarization Method:
Contact
MRC:
The means used to secure a connector to its mating counterpart.AFRV
Connector Locking Method:
Contact twistlock
MRC:
The means by which the connector cable is relieved of stress and strain.AFRW
Connector Cable Strain Relief Method:
Cord grip
MRC:
Indicates the location of the terminal/s/ on the item.CQTM
Terminal Location:
Back single mating end 1st contact grouping
MRC:
Indicates the location of the terminal/s/ on the item.CQTM
Terminal Location:
Back single mating end 2nd contact grouping
MRC:
Indicates the location of the terminal/s/ on the item.CQTM
Terminal Location:
Back single mating end 3rd contact grouping
MRC:
Indicates the type of terminal for providing electrical connection to the item.CSCF
Terminal Type:
Screw single mating end 1st contact grouping
MRC:
The number of contacts included with the item which provides electrical connection.CXCG
Included Contact Quantity:
1 single mating end 1st contact grouping
MRC:
The number of contacts included with the item which provides electrical connection.CXCG
Included Contact Quantity:
1 single mating end 2nd contact grouping
MRC:
The number of contacts included with the item which provides electrical connection.CXCG
Included Contact Quantity:
1 single mating end 3rd contact grouping