TXT
묘사:
Radio Frequency Transformer
MRC:
An indication that the level of probability that an item will operate without failure,at a specified rated capability,at a specified temperature,and for a specified period of time,has been established by testing random samples of production lot.AARG
Reliability Indicator:
Not established
MRC:
The number of turns of conductive material forming the winding.ABHY
Turn Quantity:
17 single component single secondary
MRC:
The number of turns of conductive material forming the winding.ABHY
Turn Quantity:
25 single component single primary
MRC:
The length of a straight line which passes through the center of a mounting hole,and terminates at the circumference.ABTB
Mounting Hole Diameter:
0.098 inches single group
MRC:
The value(s) of inductance inherent in the item.ACYV
Inductance Rating:
1.96 microhenries single component single secondary
MRC:
The value(s) of inductance inherent in the item.ACYV
Inductance Rating:
3.35 microhenries single component single primary
MRC:
Indicates the type of support on which the coil is wound.ACZP
Coil Form Type:
Hollow single component
MRC:
Indicates the type of drive provided for the adjustment device.ACZU
Adjustment Device Drive Type:
Slotted screw single component
MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
1.062 inches
MRC:
A measurement taken at right angles to the length of the body,in distinction from thickness.ADAT
Body Width:
1.000 inches
MRC:
A measurement from the bottom to the top of the body,in distinction from depth.ADAU
Body Height:
0.968 inches
MRC:
The distance between mounting facility centers.AEJN
Distance Between Mounting Facility Centers:
0.875 inches single mounting facility single center group
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Fully enclosed
MRC:
The number of mounting facilities provided.AKPV
Mounting Facility Quantity:
2 single group
MRC:
The means of attaching the item.AXGY
Mounting Method:
Unthreaded hole single group
MRC:
The means by which the rating is determined.BKPL
Rating Method:
Winding turns single component single primary
MRC:
The means by which the rating is determined.BKPL
Rating Method:
Winding turns single component single secondary
MRC:
The purpose and the total number of individual (not electrically connected) windings designed to perform in a transformer.BPLC
Winding Function And Quantity:
1 primary single component and 1 secondary single component
MRC:
The size of the conductor which forms the winding on the item.CQPZ
Winding Conductor Size:
0.00631 inches american wire gage single component single primary
MRC:
The size of the conductor which forms the winding on the item.CQPZ
Winding Conductor Size:
0.00631 inches american wire gage single component single secondary
MRC:
The means provided and number of adjustments included on the item.CTHD
Adjustment Method And Quantity:
2 adjustable core single component
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
4 solder stud