TXT
묘사:
Transmitter Synchro
MRC:
An alpha and/or numeric designation indicating the size by which the body is identified.AJSL
Body Size:
15
MRC:
The value of the primary excitation voltage for which the rotor is rated,expressed in volts.AJSR
Rotor Input Voltage Rating In Volts:
26.0
MRC:
The cycles per second /hertz/ of the alternating current.AJSS
Frequency In Hertz:
400.0
MRC:
The value of the primary excitation current for which the rotor is rated,with stator /secondary/ circuit open.AJST
Rotor Input Current Rating:
221.0 milliamperes
MRC:
The value of the primary /electrical/ excitation power for which the rotor is rated.AJSV
Rotor Input Electrical Power Rating:
0.6 milliwatts
MRC:
The resistance /r/ part of the rotor impedance with the stator open /zro/,expressed in ohms.AJSW
Zro Resistance In Ohms:
12.00
MRC:
The limits of permissible deviation in angular arc error from electrical zero,expressed in minutes.AJVL
Electrical Error Angular Range In Minutes:
-10.0 to 10.0
MRC:
The reactance (x) part of the rotor impedance with the stator open (zro).CQXQ
Plus J Zro Reactance In Ohms:
115.00
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
5 wire lead