TXT
묘사:
Rota Electro-mechanical Actuator
MRC:
Indicates the type of terminals for providing electrical connection to the item.AARB
Terminal Type:
Connector
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Ac
MRC:
The speed of the drive shaft required to produce the rated capacity of an item,expressed in revolutions per minute.AEQC
Operating Speed At Rated Capacity In Rpm:
0.75
MRC:
The direction of rotation of a rotating shaft as viewed from the drive end.AKCT
Shaft Rotation Direction:
Clockwise and counterclockwise
MRC:
Indicates the type of drive for turning,rotating,or positioning the mechanism.AKCV
Drive Type:
Direct
MRC:
The working period under which the item was designed to operate.AKPS
Duty Cycle:
Continuous
MRC:
The electrical current rating,expressed in amperes.AMPS
Current Rating In Amps:
0.5
MRC:
The measurement of rotation,expressed in degrees.AWQL
Rotation In Deg:
90.0
MRC:
The rated torque of the output drive.AWQM
Output Drive Torque Rating:
200.0 inch-pounds
MRC:
An indication of whether or not a limit switch control is included.AWQN
Limit Switch Control:
Included
MRC:
An indication of whether or not a manual override is included.AWQR
Manual Override:
Not included
MRC:
An indication of the rotation of the angular shaft.AWTZ
Angular Shaft Rotation:
Limited
MRC:
The facility for mounting the item.AZGM
Mounting Facility:
Open end mounting slots
MRC:
The total electrical voltage.ELEC
Voltage In Volts:
115.0
MRC:
The number of alternating current phases.FAAZ
Phase:
Single
MRC:
The cycles per second /hertz/ of the alternating current.FREQ
Frequency In Hertz:
400.0
MRC:
The justification for the assignment of a federal supply class /fsc/ to an item based on the classification of the next higher classifiable assembly.ZZZV
Fsc Application Data:
Airconditionsystem, aircraft