부품 번호 4170600-26

Electromagnetic Relay

가격 및 가용성

이 NSN의 현재 가격 및 가용성에 대해 이 양식을 제출하십시오.
부품 번호:
양:
이메일 주소:
전화:
참조:
회사:
이름:

우리는 귀하의 정보를 누구에게도 공유하거나 판매하지 않습니다.
사생활 | 용어

All major credit cards accepted as well as gov. p-cards

이 제품의 과거 가격은 3745.651 and 4898.159 USD. 수량, 가용성, 상태, 리드 타임 및 품목 중단 가능성에 따라 최신 견적을 제공할 때까지 가격을 보장할 수 없습니다.

부품 번호
비무장화
수명
UOM
NIIN
부품 번호:
4170600-26
비무장화:
No
수명:
N/A
측정 단위:
1 EA
NIIN:
000628279
NSN
국가 주식 번호:
5945-00-062-8279 5945000628279
TXT
묘사:
Electromagnetic Relay
INC
INC
아이템 이름 코드:
32512
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
3.700 inches
MRC:
The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the length.ABKQ
Center To Center Distance Between Mounting Facilities Parallel To Length:
3.250 inches single mounting facility
MRC:
The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the width.ABKR
Center To Center Distance Between Mounting Facilities Parallel To Width:
2.687 inches single mounting facility
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
4.485 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
3.305 inches
MRC:
The element,compound,or mixture of which the case is fabricated,excluding any surface treatment.ADTV
Case Material:
Metal
MRC:
The environmental elements or conditions that an item is designed or protected to resist or withstand satisfactorily.ADZC
Environmental Protection:
Hermetic
MRC:
The length of a straight line which passes through the center of an unthreaded mounting hole,and terminates at the circumference.AEBV
Unthreaded Mounting Hole Diameter:
0.218 inches single mounting facility
MRC:
The measure of sensitivity of the item to be packaged. a factor used by packaging engineers in devising proper cushioning in a package.AFJN
Fragility Factor:
Moderately rugged
MRC:
The cycles per second /hertz/ of the alternating current.AJSS
Frequency In Hertz:
400.0
MRC:
The number of individual /not electrically connected/ windings.AKDX
Winding Quantity:
1
MRC:
The purpose for which the item is designed.AKSL
Purpose For Which Designed:
General
MRC:
The number of coils included on the item.APCN
Coil Quantity:
1
MRC:
Indicates the type of duty provided.APNP
Duty Type:
Continuous
MRC:
The means of quenching an arc.APNQ
Arc Quenching Method:
Air
MRC:
Indicates the type and number of facilities by which the item is mounted.AXHR
Mounting Facility Type And Quantity:
4 unthreaded hole single mounting facility
MRC:
Indicates the type of storage space required for an item in order to provide the degree of protection necessary to maintain serviceability standards.BBRG
Storage Type:
General purpose warehouse
MRC:
A measurement of volume taken by multiplying the length by the width by the height of an item and rendered in cubic units.CBME
Cubic Measure:
39.131 cubic inches
MRC:
The general configuration and relative position of the facilities provided for mounting the item.CQYJ
Mounting Facility Pattern:
Rectangular single mounting facility
MRC:
The designation that identifies the schematic diagram of the electrical configuration of the main nonpile-up contacts including the number of poles or forms.CRNG
Nonpile-up Main Contact Arrangement:
3 pole, single throw, normally open, double make, momentary action
MRC:
The interval for which the item,by design,is purposely delayed between introduction of power into the energizing element and completion of travel of the contact carrier,and/or between interruption of the energizing power and return of the contact carrier to its normal de-energizing position.CRXH
Time Delay:
0.03 seconds fixed operate time
MRC:
The interval for which the item,by design,is purposely delayed between introduction of power into the energizing element and completion of travel of the contact carrier,and/or between interruption of the energizing power and return of the contact carrier to its normal de-energizing position.CRXH
Time Delay:
0.065 seconds fixed release time
MRC:
The designation that identifies the schematic diagram of the electrical configuration of the auxiliary nonpile-up contacts including the number of poles or forms.CSKP
Nonpile-up Auxiliary Contact Arrangement:
1 pole, single throw, normally closed, double break, momentary action and 1 pole, single throw, normally open, double make, momentary action
MRC:
The highest voltage at which the auxiliary contacts are rated for normal operation,expressed in volts.CSQC
Auxiliary Contact Maximum Voltage Rating In Volts:
115.0 ac and 28.0 dc
MRC:
The amount and type of voltage required at designated temperature to be applied to the input or energizing element of the item to ensure normal operation of the switching elements.CSXF
Operating Voltage Rating And Type At Specificationified Temp:
115.0 volts ac 25 degrees celsius single winding
MRC:
The amount of current the main contacts are rated to make or break at maximum rated voltage,with a specified load.CTDL
Main Contact Load Current Rating At Maximum Rated Voltage:
50.0 amperes ac inductive load and 50.0 amperes dc inductive load
MRC:
The amount of current the main contacts are rated to make or break at maximum rated voltage,with a specified load.CTDL
Main Contact Load Current Rating At Maximum Rated Voltage:
50.0 amperes ac motor load and 50.0 amperes dc motor load
MRC:
The amount of current the main contacts are rated to make or break at maximum rated voltage,with a specified load.CTDL
Main Contact Load Current Rating At Maximum Rated Voltage:
50.0 amperes ac resistive load and 50.0 amperes dc resistive load
MRC:
The highest voltage at which the main contacts are rated for normal operation,expressed in volts.CWAB
Main Contact Maximum Voltage Rating In Volts:
115.0 ac and 28.0 dc
MRC:
The amount of current the auxiliary contacts are rated to make or break at maximum rated voltage,with a specified load.CWGM
Auxiliary Contact Load Current Rating At Maximum Rated Voltage:
5.0 amperes ac inductive load and 5.0 amperes dc inductive load
MRC:
The amount of current the auxiliary contacts are rated to make or break at maximum rated voltage,with a specified load.CWGM
Auxiliary Contact Load Current Rating At Maximum Rated Voltage:
5.0 amperes ac resistive load and 5.0 amperes dc resistive load
MRC:
The amount of current the auxiliary contacts are rated to make or break at maximum rated voltage,with a specified load.CWGM
Auxiliary Contact Load Current Rating At Maximum Rated Voltage:
750.0 milliamperes ac lamp load and 750.0 milliamperes dc lamp load
MRC:
The specification,standard,drawing,or similar instrument that specifies environmental and performance requirements or test conditions under which an item is tested and establishes acceptable limits within which the item must conform identified by an alphabetic and/or numeric reference number. includes the commercial and government entity (cage) code of the entity controlling the instrument.TEST
Test Data Document:
81349-mil-r-6106 specification (includes engineering type bulletins, brochures, etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "", etc.).
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
12 threaded stud all functions
MRC:
The document designator of the specification or standard which established the item of supply.ZZZK
Specification Data:
96906-ms24376 government standard

{lang[cimilar]} Electromagnetic Relaies

« Relays and Solenoids {lang[catalog]}
지금 비교»
맑다 | 숨기다