MRC:
The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
Operating Tempurature Range:
+0.0/+50.0 degrees celsius
MRC:
The frequency at which the insertion loss is measured per function,and to which all related attenuation loss measurements are referred.AHAJ
Reference Frequency Per Function:
60.0 kilohertz blank
MRC:
The total opposition per function with load (resistive and reactive) presented by the device to the source (asa c42.65,paragraph 65.08.399).AHAU
Input Impedance Per Function W/load:
75.0 ohms blank
MRC:
The total opposition per function with source across input (resistive and reactive) presented by the device to the load (asa c42.65,paragraph 65.08.402).AHAV
Output Impedance Per Function W/source Across Input:
75.0 ohms blank
MRC:
Indicates the type of principal circuitry per function interconnected within the item to produce the desired frequency versus attenuation characteristics.AHBL
Principal Circuitry Type Per Function:
Inductance-capacitance-resistance blank
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Encased
MRC:
The ratio per function of the power delivered to the load before insertion of the filter to the power delivered to the load after insertion of the filter,expressed in decibels.CQDR
Insertion Loss At Reference Frequency Per Function In Decibels:
0.6 blank
MRC:
The specified frequencies,per function,at which losses in signal strength are,by design or measurement,established in a filter circuit.CQFC
Specified Frequencies Of Discrimination Per Function:
300.00 hertz blank and 8.00 kilohertz blank and 12.00 kilohertz blank and 108.00 kilohertz blank
MRC:
The difference,per function,between the limiting frequencies within which performance,in respect to some characteristic,falls within specified limits.CRBB
Frequency Band Width Per Function:
12.00 kilohertz blank and 108.00 kilohertz blank
MRC:
The algebraic difference between the insertion loss at a specified frequency and the insertion loss at the reference frequency per function,expressed in decibels.CRBC
Discrimination At Specificationified Frequencies Per Function In Decibels:
25.0 blank and 25.0 blank and 0.6 blank and 0.6 blank